Dustcontrol DC 4000 PCB Notice Originale page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
TROUBLE SHOOTING
Problem
Motors will not start.
The motors stop directly
after starting.
Pump runs but no suction.
Pump runs but poor suction.
Machine blows dust.
Abnormal sound from
machine.
2014-10-06
Fault
Machine not connected.
Incorrect fuse.
Thermal overload not set
correctly.
Hose not connected.
Hose plugged.
No plastic sack on the
cyclone.
The container is not fi rmly
attached to the bottom of
the cyclone.
Hole in the hose.
Plugged fi lter.
Hose too long or too small.
Hose is kinked.
Machine top is mounted
incorrectly.
Dust is packed in the
cyclone.
One of the fans is turned
off .
Filter is perforated or has
come loose.
DC 4000 PCB - 12
Solution
Make sure connection.
Change to correct circuit.
Electrician should adjust.
Connect the hose.
Find and remove block.
Mount the correct sack.
Secure the container.
Change or repair hose.
Clean or change fi lter.
Change the hose.
Check and free.
Adjust the mounting.
Take off the top and clean
out.
Start it.
Check the fi lters and change
if necessary.
Order service.
Part No 94162-C

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

94162-c

Table des Matières