English
1. General
See start of document.
1.1 Application
With the Jet-pump WlLO offers an inexpensive
water supply unit in the fields of home, hobby and
garden. The pumps are suitable for:
– watering and sprinkling from ponds, creeks and
bores,
– draining of tanks and containers,
– dewatering of flooded basements.
The pump works self-priming (e.g. from bores) or
with flooded suction (e.g. from open tanks).
It must not be connected directly to public water
supply systems.
1.2 Product Information
1.2.1 Technical Data
Suitable media: Water without solid particles,
domestic, cold, cooling and rain water. Use of
other media requires WlLO's consent.
• Temperature min./max. :
• Environment temperature min./max. :
• Maximum suction lift :
• Single-phase (EM):
• Three-phase (DM):
• Size suction/discharge ports:
• Max. working pressure:
• Insulation class:
• Protection index:
• Electrical connection:
When ordering spare parts, please state all name
plate data.
2. Safety
See start of document.
3. Transport and Storage
ATTENTION! The pump must not be subjected to
temperatures outside the limits of 0 °C to +
40 °C.
If the equipment delivered is to be installed at
some later time, store it in a dry place and pro-
tect it from impacts and all external influences
(moisture, frost, etc.).
Handle the pump carrefully so as not to alter the
geometry and the alignment of the hydraulic
unit.
Never suspend the pump from the power cord.
22
+ 5 °C to + 35 °C
0...40 °C
8 m
2850 1/min (50 Hz)
3450 1/min (60 Hz)
G1"
6 bar
130
IP 44
1 ~ 230 V ±6%, 50 Hz /
3 ~ 400 V ±6%, 50 Hz /
1 ~ 220-240 V ±6%, 60 Hz
3 ~ 220-254/380-440 V
±6%, 60 Hz
4. Description of Product and Accessories
All WJ-series pumps are self-priming. AlI parts
in contact with the medium being handled are of
corrosion-resistant steel. Single-phase motors
have built-in thermal contacts, switching off the
motor on overload and on again after a cooling
down period. A mechanical seal separates the
pump housing from the motor.
ATTENTION! The pump must not run dry.
Warranty does not cover damages to the pu mp
due to dryrunning.
4.1 Description of WJ-Series Pump
Series WJ pumps are portable for mobile applica-
tion. Single phase pumps have a carrying grip and
are supplied complete with power cable, plug
and ON/OFF switch.
Standard-Installations
– Figure 1: Pump in suction
– Figure 2: Pump under pressure on storage tank or
on town water supply with dry-running protec-
tion system.
Legend for Installation samples (see figures 1 and 2):
Pos. 1 Strainer-foot valve
(maximum passing section 1 mm)
Pos. 2 Pump suction valve
Pos. 3 Pump discharge valve
Pos. 4 Non-return valve
Pos. 5 Filling plug
Pos. 6 Draining plug
Pos. 7 Pipe supports
Pos. 8 Strainer
Pos. 9 Storage tank
Pos. 10 Town water supply
Pos. 11 3~ motor protection relay
Pos. 12 OFF/ON switch for single phase motor
(red indicator light)
Pos. 13 Power plug (1~ -Motor)
4.2 Scope of supply
– Jet Pump (WJ)
– Installation and Operation instructions.
4.3 Accessories
– Suction kit,
– Isolating valves,
– Non-return valves,
– Strainer-foot valve,
– Bladder tank,
– Vibrationless sleeves,
– Motor protection relay,
– Dry running protection (ME kit),
– On-off control device...
The use of new accessories is recommended.
WILO SE 08/2017