(*) These data refer to Fig. 1. Measurements are expressed in millimetres.
The minimum priming level corresponds to a condition in which the delivery mouth is completely submersed.
(See Fig. 1 - Reference A)
CHAP. 3 INSTALLATION
Please use handlebar to remove or lift pump up.
Please use a non-return valve in case pump is connected to fixed installation with rigid piping; this will avoid liquid
circulating when pump has been turned off; use of a pipe fitting will allow easy disconnection of pump for maintenance.
Dimensions of drain well must allow max. 30 on/off cycles/hour. ( See USE AND HIS LIMITATIONS )
Please use flexible pipe connected to pump by means of plastic fitting in case of temporary use of pump.
Use a rope to immerse pump and fasten it to pump's handlebar.
OMNIA® aut is equipped with a pre-rated float switch ( See Pict. 1 ); please increase or decrease the free piece of float
switch cable by making it sliding through the proper seat on the handlebar, when modifying the rating of float switch.
Pumps used besides garden ponds or similar places may have special requirements.
CHAP. 4 ELECTRIC CONNECTION
The supply cord is equipped with double ground contact, plug so grounding is done when plugging in.
Overload protection
OMNIA® range pumps have a built-in thermal overload with automatic reset.
Further protections are not required.
CHAP. 5 MAINTENANCE AND TROUBLE SHOOTING
DANGER
Electric shock risk
DANGER
REMARK
REMARK
REMARK
DANGER
Electric shock risk
DANGER
Electric shock risk
DANGER
Electric shock risk
DANGER
Electric shock risk
When installing, please ensure pump is disconnected
from electric current network. Pumps in this series
are not suitable for use in a swimming pool and the
relevant cleaning and servicing operations.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory or
mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to ensure that they do
not play with the appliance.
Make sure that float switch turns off pump, when at
min. level of liquid.
Make sure no obstacles stand in the way of float
switch, during up/down swinging.
Ensure tension and frequency of pump (read motor
plate) and supply network are same.
Installer must make sure that electric current network
has ground wire conforming to current laws.
Make sure that electric current network is provided
with a high-sensitivity circuit-breaker
∆ ∆ ∆ ∆ ∆
=30 mA (DIN VDE 0100T739)
Before doing any operation, make sure pump
is disconnected from electric current network.
Power cord must be replaced by
manufacturer or by Customer service, using
special tools.
GB
5