Operating instruction for electric fence controller
Scout N2 for pigeon control
Installation and connection
The electric fence controller is designed acc. EN 60335-2-76 to supply electric fences for
deterring pigeons from roosting on buildings. The installation can be made inside or outside
a building but not where there is a risk of fire. In case of outside installation the controller must
be mounted in the vertical position.
The two fence leads must be connected to the output terminals marked with
The earth terminal (
) must not be grounded.
In case of indoor installation each fence lead must be equipped with a lightning
suppression outside the building. If the building is protected with lightning arrestor installation
the earth of the fence arrestor must be connected to the earth of the building arrestor. If there
is no building arrestor a special grounding must be provided - be aware of possible
requirements of local authorities.
In case of energizer outdoor installation a lightning suppression in each lead is recommended.
Battery- and solar operated energizers need no lightning suppression.
Operation and control - handling the arguswitch
Plug the mains cable in a 220-240 supply socket. After a few seconds a slight tic-tac can be
heard. The fence control lamp flashes with the pulses. There will be no flashing if the fence
voltage drops below a minimum voltage of 2000 V.
possible reasons:
1) fence disconnected: controller faulty, check the fuse under the window.
2) fence attached:
contact between the fence leads,
moist foilage, water,snow, dirt etc.
arguswitch
The controller has two output settings, see explanation sketch.
In position high > thick lightning arrow < the output is high enough to overcome a slight
connection between the fence leads - the fence control lamp remains flashing. The fence
cannot be checked, the fence voltage is still over 2000 V.
Pressing the arguswitch button acc. to the pictogramm now the lamp is able to detect fence
faults. A second option of the arguswitch is to switch the output to a reduced level > thin
li ghtning arrow <.
Requirements
The controller complies with the safety standard for electric fence controllers EN 60335-2-
76 and the EMC standards - CE mark.
Service
A fuse ( T 500mA ) and plug in moduls can be replaced easily by your dealer - see list of
components. First of all check the fuse. If the supply cord is damaged this cord must be
replaced by a special supply cord which is recommended by the manufacturer.
4
and
Technical changes reserved !
2
3
7
6
fig. A
10 mm
1 electric fence controller
2 arrestor kit (see fig.A)
3 switch
(see fig.B)
4 high voltage cable
5 insulated wall conduit
6 earth rod (1m moisty ground )
7 grounding for building lightning arrestor
8 fence leads
fig. B
switch
switch
in position a)
in position b)
fence wire hot
fence wire earthed
1
4
5
8
5