Gather the required tools before starting installation. Read and
follow the instructions provided with any tools listed here.
Tools needed
³⁄₈" combination wrench
½" combination wrench
⁵⁄₈" combination wrench
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
IMPORTANT: Gas conversions must be done by a qualified
installer. Before proceeding with the conversion, shut off the gas
supply to the range prior to disconnecting the electrical power.
GAS CONVERSIONS
Tools Needed
7 mm (⁹⁄₃₂") nut driver
Quadrex
Masking tape
Plastic bag for replaced parts
†® QUADREX is a registered trademark of NLW Holdings, Inc.
Gas Conversions
This conversion kit shall be installed by a
qualified service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements of
the authority having jurisdiction. If the
information in these instructions is not
followed exactly, a fire, explosion or
production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation is
not proper and complete until the
operation of the converted appliance is
checked as specified in the
manufacturer's instructions supplied with
this kit.
1. Turn the manual shutoff valve to the closed position.
2. Unplug range or disconnect power.
®†
or Phillips screwdriver
WARNING
A
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply line
B
C
3