Electrical Connection To The Range - Frigidaire FFES3026TW Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

30" ELECTRIC SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
5.
Electrical Connection to the
Range (U.S.A.)
Three Conductor Wire Connection to
Range
If local codes permit connection of the frame grounding
conductor to the neutral wire of the copper power
supply cord (see Figure 3):
1. Remove the screw which is fixing the rear wire
cover, then remove the rear wire cover (access
cover) to expose range terminal connection block
(see Figure 2).
2. Using the nuts supplied in the literature package,
connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal) (see figure 3).
3. Put back the rear wire cover using the screw
removed on step 1.
Grounding
Strap
Terminal
Block
Black
Wire
A User Supplied
Strain-relief Must
To 240 V
Be Installed at This
Receptacle
Location.
Figure 3
Silver Colored Terminal
Red Wire
Cord
Mounting
Plate
Neutral
(White Wire)
1 1/8" (2,9 cm) Dia.
Direct Connection
Hole. Punch Out
Knockout for 1 3/8"
(3,5 cm) Dia. Cord
Kit Hole.
Four Conductor Wire Connection to Range
Where local codes does NOT permit connection of the
frame grounding conductor to the neutral wire of the
copper power supply cord (see Figure 4):
1. Remove the screw which is fixing the rear wire
cover, then remove the rear wire cover (access
cover) to expose range terminal connection block
(see Figure 2).
2. Remove the grounding strap from the terminal
block and from the appliance frame.
3. Using the nuts supplied with the literature package,
connect the ground wire (green) of the copper
power supply cord to the frame of the appliance with
the ground screw, using the hole in the frame where
the ground strap was removed (see Figure 4).
4. Connect the neutral of the copper power supply
cord to the center silver-colored terminal of the
terminal block, and connect the other wires to the
outer terminals. Match wires and terminals by color
(red wires connected to the right terminal, black
wires connected to the left terminal).
5. Put back the rear wire cover using the screw
removed on step 1.
Terminal Block
Black Wire
1 1/8" (2,9
cm) Dia.
Direct
Connection
Hole. Punch
Out Knockout
for 1 3/8" (3,5
cm) Dia. Cord
Kit Hole.
A User Supplied
Strain-relief Must
Be Installed at
This Location
NOTE: Be sure to remove
the supplied grounding strap.
7
Silver Colored Terminal
Neutral
(White Wire)
Ground (Bare
Copper Wire)
To 240 V
Receptacle
Figure 4
Red
Wire

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ffes3026tbFfes3026tsFges3045kfFpcs3085lf

Table des Matières