11. Low ventilation indicator
en
12. Power indicator
13. ON/OFF (power) button
CZ
14. "Full Water" indicator
15. TIMER button
DE
Please note, the indicator in the front plate will light on in
3 different colors to reflect the ambient humidity level. By
DK
this, the user can understand immediately what the am-
bient humidity condition is:
EE
Blue light – room humidity > 70%
Green light – room humidity 50~70%
ES
Red light –room humidity < 50%
Red light flash – water full alarm
FI
Operation
1. Plug the unit into a correct mains socket. (Please refer
FR
to the rating label at the rear of the unit for correct vol-
tage/frequency.)
GB
2. Press ON/OFF button to turn on the unit. The compres-
sor will start to work.
3. Press humidity setting button to set the working model
HR
you need: continuous working, humidity 40%, 50%,
60% or 70%. The relative indicator will light on.
HU
4. Press speed/ventilation button to set the ventilation
speed, high or low. The relative indicator will light on.
IT
5. Press the TIMER button to set the operating hour you
need (1~24 hours). The display window will show the
hour(s) you set as you press the TIMER button, after
LT
releasing it for 8 seconds around, the display window
will return to the room humidity. As the set time has
LV
been reached, the compressor will stop working auto-
matically.
NL
6. By pressing the "TEMP" button, the display window will
show the room temperature, after releasing the button
for 8 seconds around, the display window will return to
NO
the room humidity.
7. DRYER function is turbo ventilation to dry the moistu-
PL
re in the air continuously, so it could help to dry the
laundry.
RO
8. To turn off the unit, press ON/OFF button again.
9. Pre-setting function By pressing TIMER button but wit-
hout turning on the other functions (including ON/OFF
RU
button), you can PRE-SET the time for the machine to
work. For example, if you press the timer to '2', the unit
SE
will work automatically after 2 hours
SI
6. DRAINAGE
While the water tank is full, the compressor will stop for
SK
self-protection and the water full indicator will turn into red.
To move the water tank, pull it out squarely from the unit.
After empting the water tank, place the water tank into spa-
UA
ce. Make sure it is properly positioned, in order for the 'wa-
ter full' sign to go out and your dehumidifier is operating.
SE
Please note, in case, the water tank has not been positio-
ned well, the water full indicator will turn into red.
SI

CONTINUOUS DRAINAGE

When the dehumidifier is operated at very high humidity
SK
levels, the water tank will require more frequent drainage.
In this situation, it may be more convenient to set the unit
TR
up for continuous drainage with the following procedures:
1. Pull out the water tank (FIG. 5).
UA
2. Connect the drain hole with water tube of inner diame-
ter: 11 mm. The water tube is not supplied with the unit
(FIG. 6).
3. Ensure the water will always drain away freely and the
tube will remain in right place. Note! In very cold weather
conditions, precautions should be taken to prevent the wa-
ter tube from freezing.
4. Put the water tank back to its position.
7. MAINTENANCE
Always unplug the unit from the mains before carrying out
any maintenance or cleaning of the unit.
CLEANING THE BODY
Use soft cloth to wipe the unit clean.
Don't ever use volatile chemicals, gasoline, detergents,
chemically treated clothes, or other cleansing solutions.
These all could possibly hurt the cabinet.
CLEANING THE FILTER
This dehumidifier is equipped with 2 filters (FIG. 7):
1. ANTI-DUST FILTER
Extract the filter holder, remove the active carbon filter.
Use a vacuum cleaner or tap the filter lightly for easy clea-
ning. If the filter is particularly dirty, use warm water with
a small amount of a small amount of medium strength
detergent.
Make sure the filter is completely dry before replacing.
Do not expose the filter to sunlight.
2. ACTIVE CARBON FITLER (for capturing the particles
of dust suspended in the air and preventing the produc-
tion of bacteria.)
The active carbon filter placed under the anti-dust filter is
not washable. Its life span is variable and depends on the
ambient conditions where the unit is used. The filter should
be checked periodically and replaced if necessary.
STORAGE
If not use the unit for an extended period of time. Please:
Turing the unit off, unplug and tidy AC cord.
► Completely empty the water tank and wipe it clean.
► Cover the unit and store where it will not receive direct
sunlight.
8. TROUBLE SHOOTING
THE UNIT DOES NOT OPERATE:
► Is the unit plugged in?
► Is the house electricity on?
► Is the room temperature below 5
so, then it is out of the working range of the unit.
► Ensure the humidistat (or ON/OFF switch) is turned
on.
► Check the water tank is positioned properly in the unit
and it is not full.
► Make sure the air inlet and outlet are not obstructed.
THE UNIT SEEMS TO DO NOTHING:
► Is the filter dusty, contaminated ?
► Is the air intake or outlet blocked up?
► Is the room humidity already quite low?