Electric connections accessories
11.3 Couple through eBus contact;
Important:
Because of polarity sensitivity, always connect contacts X1-1 to X1-1 and contacts X1-2 to X1-2. Never connect
X1-1 and X1-2.
230V
50Hz
For M (Master):
Set parameter 9 to 0 (= factory setting).
Display shows ventilation mode 1, 2 or 3.
A
=
Multiple switch
B
=
2-pole connector
M
=
Renovent Excellent (Master)
C1 t/m C*
=
Renovent Excellent (Slave); couple
not more than 10 appliances through Ebus
set as "Master".
230V
50Hz
230V
50Hz
For C1 (Slave1):
set parameter 9 to 1 (= Slave 1).
Display always shows ventilation
E
Step
nr.
30
31 Sensitivity
Renovent Excellent
230V
50Hz
For C2 (Slave2):
Set parameter 9 to 2 (= Slave 2).
Display always shows ventilation
Step
Factory
Description
nr.
setting
Communica-
8
eBus
tion type
9
eBus address
A = Renovent Excellent
B = Control board
C = RH (huminity) - sensor
D = Cable supplied with RH sensor
E = Duct from dwelling
C1
= brown
C2
= blue
C3
= green/yellow
Factory
Description
setting
Activating
OFF
RH-sensor
0
Chapter 11
A maximum of 10 appliances
(1 Master + 9 Slave max.)
Range
0t ( = Opentherm)
eBus
0 = master
0
1- 9 = slave 1 - 9
Range
OFF = not active
ON = active
-2 most ensitive
-1
0 default setting RH-sensor
+1
+2 least sensitive
33