Cleaning The Device - Urmet 1092/225 Manuel D'utilisation

Caméra compacte day & night 700 tlv avec zoom 10x 5-50 mm
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DESCRIPTION OF THE SPECIAL MENU
In order to access to the SPECIAL menu, the following movements are necessary on the menu button:
DOWN – UP – RIGHT – LEFT - ENTER
The following menu will appear.
Option
ADDR
BAUD
OSD-DISP
ADDR-DISP
D-ZOOM
AUTO FOCUS
EXIT
CAMERA MANAGEMENT WITH CONTROL KEYPAD
The camera can be remotely managed by any control keypad equipped with RS-485 interface (for ex. the
keypad 1092/693); in this case, the communication parameters must be manually configured via camera
menu (as above described), in order to match the keypad ones (ID, Protocol, Baud Rate).
From camera menu, that can be accessed by the control keypad, the user can perform all the
customizations, as described in this manual.
Use the following commands:
PRESET 95 to access to the Menu
the Joystick to scroll the Menu options and change their values
IRIS+/Open to enter or exit into/from the submenus
Note
For keypad specific functions and access commands, see the control keypad manual

CLEANING THE DEVICE

Rub delicately with a dry cloth to remove dust and dirt.
Dip the cloth in neutral detergent if dirt cannot be eliminated with a dry cloth alone.
Do not use volatile liquids (such as petrol, alcohol, solvents, etc.) or chemically treated clothes to
clean the device to prevent deformation, deterioration or scratches to the paint finish.
32
Value
00 ÷ 255
1200 ÷ 115200
ON ÷ OFF
ON ÷ OFF
ON ÷ OFF
ON ÷ OFF
Explanation
It selects the camera address connected in RS-
485
It selects the Baud Rate in the RS-485
communication
It enables the menu info on the display
It enables the address info on the display
It enables the Digital Zoom
It enables the Auto Focus
Exit from SPECIAL menu
DS1092-171

Publicité

Table des Matières
loading

Table des Matières