4.6 Pin connections

Information on the temperature contacts
Depending on the version ordered, the temperature contacts could be in the
form of a normally closed (T70 N/C), Pt 100 or 4 - 20 mA output temperature
contact.
Version TC...C 1.x /-S12-Vxxx
On site
Version TC...D 1.x /-S12-Vxxx
On site
Version TC...C 1.x /-S44-Vxxx
On site
Version TC...D 1.x /-S44-Vxxx
On site
42
Connection A
Connection B
On site
M12x1, 4 pole
M12x1, 4 pole
Level
Temperature
T 70/Ö
Connection A
Connection B
On site
M12x1, 4 pole
M12x1, 4 pole
Level
Temperature
Connection A
M12x1, 4 pole
Level and Temperature
Connection A
M12x1, 4 pole
Level and Temperature
4.7 Technical specifi cations for fl uid level and
temperature contacts and plug types
Version TC...C 1.x /-S12-Vxxx
Fluid level switch points:
Bi-stable NO / NC
Max. 2 can be set
Resolution
10 mm
Hysteresis
4 mm
Thermal contact
T70 °C / N/C
Switching capacity
10 W / VA max.
30 V / DC max.
Switching current
1 A max.
Plug connections
Connection A
Level contact(s):
1 = 15 V - 30 V DC
2 = level L1 (+UB)
3 = not used
4 = level L2 (+UB)
Version TC...D 1.x /-S12-Vxxx
Fluid level switch points:
Bi-stable NO / NC
Max. 2 can be set
Resolution
10 mm
Hysteresis
4 mm
Thermal element
Pt 100
Temperature switch points
Max. 2 can be set
Hysteresis
1 - 99 K can be set
Switching capacity
10 W / VA max.
30 V / DC max.
Switching current
1 A max.
Display for temperature monitoring
LED 3-digit (4-digit if unit of meas. not shown)
Display range
-20 °C to +120 °C (-4 °F to +248 °F)
Plug connections
Connection A
Level contact(s):
1 = 15 V - 30 V DC
2 = level L1 (+UB)
3 = not used
4 = level L2 (+UB)
Version TC...C 1.x /-S44-Vxxx
Fluid level monitoring:
Output signal
4 - 20 mA
Measuring range for V 250
165 mm
Measuring range for V 370
285 mm
Measuring range for V 520
435 mm
Resolution
4 mm
Hysteresis
0 - 10 %
Temperature monitoring:
Output signal
4 - 20 mA
Measuring range
0 - 100 °C
Hysteresis
0 - 1 K
Ohmic resistance
U
- 8 V
B
R
=
B
20 mA
Signal transmission
Screened cable must be provided!
Plug connection
Connection
Fluid level and temperature signals:
1 = 15 V - 30 V DC
2 = temperature 4 - 20 mA
3 = not used
4 = fl uid level 4 - 20 mA
Connection B
Temperature contact(s):
1
= 15 V - 30 V DC
2+4 = T70 / Ö (+UB)
3
= not used
Connection B
Temperatue contact(s):
1 = 15 V - 30 V DC
2 = temperature 2 (+UB)
3 = GND (0 V)
4 = temperature 1 (+UB)