7. List of the main commands
Selection and configuration
CHA+ / CHA-
FCT0 ...9...A...F
MM / IN
KEY0 / KEY1
MUL [+/-]xxx.xxxx
PRE [+/-]xxx.xxx
E
REF1 / REF2
STO1 / STO0
TOL ON / TOL OFF
ECO1 / ECO 0
LCAL dd.mm.yy
NCAL dd.mm.yy
NUM x...x (up to 20chars) Modify the instrument number
TOL +/-xxx.xxx +/-yyy.yyy Inputting tolerance limits
MIN /MAX /DEL /NOR
CLE
UNI1 / UNI0
OUT1 /OUT0
PRE ON / PRE OFF
PRE
SET
RES1 / RES2
SBY xx
BT0/BT1
BTRST
Interrogation
CHA?
FCT?
UNI?
KEY?
MUL?
PRE?
REF?
STO?
TOL?
ECO?
LCAL?
NCAL?
NUM?
?
MOD?
SET?
ID?
sion
BAT?
OFF
RST
SBY
MAC?
Change measurement direction
Assign «favourite» function
Change measurement unit
Lock / unlock keypad
Modify multiplication factor
Modify preset value
Change active reference
Activate / de-activate HOLD
Activate / de-activate tolerances
Activate / de-activate economic mode
Modify last calibration date
Modify next calibration date
Selecting MIN, MAX, Delta, Normal mode
Re-initialisation of MIN, MAX or Delta
Activate / de-activate change of units
Activate / de-activate contin. data transmission
Activate / de-activate Preset function
Recall Preset
Zero reset
Change of resolution
xx number of minutes before stand-by
Activate / de-activate Bluetooth
Reset pairing information
Measurement sense?
«favourite» function active?
Measurement unit active?
Keypad locked?
Multiplication factor?
Preset value?
Reference active?
Status of HOLD function?
Current tolerance limit values?
Current economic mode
Date of last calibration?
Date of next calibration?
Instrument number?
Current value (mode Tol, value followed by <=>)
Active mode (MIN, MAX, Delta or Normal)?
Main instrument parameters?
Instrument identification code?
Maintenance functions
Battery status (BAT1 = OK, BAT0 = low battery)
Switch-off (wake up using a button or RS)
Re-initialisation of the instrument
Put instrument in stand-by (SIS)
Bluetooth
MAC address ?
®
16
Interrogation
CHA?
FCT?
UNI?
KEY?
MUL?
PRE?
REF?
STO?
TOL?
ECO?
LCAL?
NCAL?
NUM?
?
MOD?
SET?
ID?
Maintenance function
BAT?
OFF
RST
SBY
module
®
Measureme
«favourite»
Measureme
Keypad loc
Multiplicatio
Preset valu
Reference a
Status of H
Current tole
Current eco
Date of last
Date of nex
Instrument
Current valu
Active mod
Main instrum
Instrument
Battery stat
Switch-off (
Re-initialisa
Put instrum

Publicité

Table des Matières
loading

Produits Connexes pour sylvac PS16 V2

Table des Matières