Electrical Connection - Franke FDF 9174 I Mode D'emploi Et Installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ELECTRICAL CONNECTION

• Connect the hood to the mains through a two-pole
switch having a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Mainte-
nance) being sure that the connector of the feeding
cable is correctly inserted in the socket placed on the
side of the fan.
• Connect the control connector Cmd.
• Connect the lights connector Lux.
• Place the connectors in the junction box 24 and close
it using the 2 screws 12e (2,9 x 9,5) provided.
• Fix the junction box to the hood body using the 2
screws 12c (2,9 x 6,5) provided.
• For the recirculation version, fit the activated carbon
odour filter.
• Replace the grease filters.
EN
24
12e
12c
Lux
Cmd
2
23
3