Dia-
Description of Transparent Parameters
gram
Antifreeze liquid protection rating (%)
P18
Solar Circulating Pump output operation
P19
mode
(0=OFF continuous, 1=auto and 2=ON
continuous)
FREE CONTACT relay operation mode
P20
(0=OFF continuous, 1=auto, 2=ON conti-
nuous, 3=Boiler activation/deactivation)
Minimum - Solar Circulating Pump modula-
P21
tion temperature differential (°C)
Solar Circulating Pump modulation tempe-
P22
rature differential (°C)
Solar Circulating Pump operation (0=On/
P23
Off, 1=Modulating)
Hot water tank limit temperature (°C)
P24
Flowmeter type selection (0=Operation
P25
without fl owmeter, 1=DN8, 2=DN10,
3=DN15, 4=DN20, 5=DN25)
Operation type selection (DO NOT MODI-
P26
FY)
Press the Up/Down buttons to scroll the list of parameters, in increasing or
decreasing order respectively. To change the value of a parameter just press
the Enter button in relation to the parameter and then modify the parameter
with the Up/Down buttons: the change will be automatically saved.
Press the Enter button to return to the list of parameters.
Press the Info button to return to the Service Menu. Press the Info button
for 10 seconds to exit the Service Menu or exiting is automatic after 15
minutes.
"In" - Information Menu
The regulator can display the following information:
S1: Upper Hot Water Tank PT1000 Sensor
t01
(°C)
Only with System 2 or System 3
S2: Hot Water Tank NTC Sensor (°C)
t02
S3: Solar Collector PT1000 Sensor (°C)
t03
S4: Solar Collector Return NTC Sensor (°C)
t04
Only with System 1 or System 3
Solar circuit fl ow rate (Lt_min)
F05
Only with Flowmeter connected and activated
Actual modulating circulating pump speed
P06
(40%=Speed 1 ¸ 100%=Speed 5)
Press the Up/Down buttons to scroll the list of information. To display the
value just press the Enter button in relation to the parameter. In case of
damaged Sensor, the regulator displays hyphens.
Press the Enter button to return to the list of information.
Press the Info button to return to the Service Menu. Press the Info button
for 10 seconds to exit the regulator Service Menu or exiting is automatic
after 15 minutes.
"Hi" - History menu
The microprocessor can memorise the total hours with regulator fed (Ht),
the last 10 boiler faults and other information; the History datum item H1:
represents the most recent fault that occurred; the History datum item H10:
represents the least recent fault that occurred.
No. hours ECOTRONIC Tech opera-
Ht
tion (Supply)
Fault code
H01
Fault code
H02
Fault code
H03
Fault code
H04
Fault code
H05
42
Range
Default
0-50%
25%
0-2
1=Auto
0-3
1=Auto
5-20°C
10°C
2-20°C
5°C
0-1
1
70-95°C
80°C
0-5
0
0-1
1
between 01 and
175°C
between 01 and
125°C
between 01 and
175°C
between 01 and
125°C
00-99 Lt_min
0-100%
between 0 and 9999 hours
Cod. 3540V701 - Rev. 01 - 04/2014
Fault code
H06
Fault code
H07
Fault code
H08
Fault code
H09
Fault code
H10
No. hours Solar Circulating Pump
H11
operation
No. hours AUX1 output relay opera-
H12
tion
No. hours AUX2 output relay opera-
H13
tion
No. hours FREE CONTACT output
H14
relay operation
Max. temperature S1: Upper Hot
H15
Water Tank PT1000 Sensor (°C)
Only with System 2 or System 3
Max. temperature S2: Hot Water Tank
H16
NTC Sensor (°C)
Max. temperature S3: Solar Collector
H17
PT1000 Sensor (°C)
Max. temperature S4: Solar Return
H18
Collector NTC Sensor (°C)
Only with System 2 or System 3
No. litres solar circuit (litres)
H19
Only with Flowmeter connected and
activated
Average circulating pump speed (%)
H20
Cumulative calculation performed
only if the circulating pump is working
Thermal Quantity Balance (kWh)
BIL
Cumulative calculation performed
only if the circulating pump is working
Press the Up/Down buttons to scroll the list of faults. To display the value
press the Enter button in relation to the parameter.
Press the Enter button to return to the list of faults.
Press the Info button to return to the Service Menu. Press the Info button
for 10 seconds to exit the card Service Menu or exiting is automatic after
15 minutes.
"rE" - History Reset
Press the ON/OFF button for 3 seconds to delete all the information stored
in the History Menu: the card will automatically exit the Service Menu, in
order to confi rm the operation.
Press the Info button for 10 seconds to exit the card Service Menu or exiting
is automatic after 15 minutes.
between 0 and 9999 hours
between 0 and 9999 hours
between 0 and 9999 hours
between 0 and 9999 hours
between 01 and 175 °C
between 01 and 125 °C
between 01 and 175 °C
between 01 and 125 °C
between 0 and 9999 litres
0-100%
between 0 and 9999 kWh