Ferroli 0XBM2CX0 Instructions Pour L'installation Et L'entretien

Ferroli 0XBM2CX0 Instructions Pour L'installation Et L'entretien

Colonne solaire multifonction
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

Colonna Solare Multifunzione
Multifunction Solar Column
Colonne Solaire Multifonction
ISTRUZIONI PER L'USO, L'INSTALLAZIONE E LA MANUTENZIONE
USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS
INSTRUCTIONS POUR L'INSTALLATION ET L'ENTRETIEN

Publicité

Table des Matières
loading

Sommaire des Matières pour Ferroli 0XBM2CX0

  • Page 1 Colonna Solare Multifunzione Multifunction Solar Column Colonne Solaire Multifonction ISTRUZIONI PER L’USO, L’INSTALLAZIONE E LA MANUTENZIONE USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTRUCTIONS POUR L'INSTALLATION ET L'ENTRETIEN...
  • Page 2: Table Des Matières

    Colonna Solare Multifunzione SOMMARIO AVVERTENZE ............................3 1. PRESENTAZIONE ..........................3 2. INSTALLAZIONE ..........................3 AVVERTENZE ........................................... 3 SCHEMI DI COLLEGAMENTO ....................................5 SEQUENZA DI INSTALLAZIONE ....................................8 3. MESSA IN SERVIZIO ........................8 CALCOLO DELLA QUANTITÀ DI FLUIDO SOLARE PER IL RIEMPIMENTO DELL’IMPIANTO ................8 MESSA IN SERVIZIO CIRCUITO SOLARE ................................
  • Page 3: Avvertenze

    La ringraziamo di aver scelto una colonna solare multifunzione FERROLI, un prodotto di concezio- come previsto dalla legislazione vigente. La mancata adozione di adeguate misure e/o dispositivi di ne avanzata, tecnologia d’avanguardia, elevata affi...
  • Page 4 Colonna Solare Multifunzione In dotazione con il sistema solare forzato ECOTOP VRF è fornita una delle seguenti scatole accessori e raccordi: 072226X0 (per bollitore 200 lt. e n° 1 ECOTOP VRF) 072225X0 (per bollitore 300 lt. e n° 2 ECOTOP VRF) 072224X0 (per bollitore 300 oppure da 500 lt.
  • Page 5: Schemi Di Collegamento

    Colonna Solare Multifunzione SCHEMI DI COLLEGAMENTO Nei disegni sottostanti sono riportati gli schemi di collegamento tra gli elementi contenuti nel sistema. Fare riferimento ai codici dei componenti riportati sulle singole confezioni. (fi g. 2) Schema con collettori piani ECOTOP VRF 0XCK2RXA 0XCK2RXA 0XCK2RXA...
  • Page 6 Colonna Solare Multifunzione In dotazione con il sistema solare forzato ECOTUBE è fornit una delle seguenti scatole accessori e raccordi: 072195X0 (per bollitore 200 lt.) 072196X0 (per bollitore 300 lt.) Installare e collegare i componenti come indicato nello schema. I componenti indicati con " "...
  • Page 7 Colonna Solare Multifunzione Schema con collettori sottovuoto ECOTUBE 0XAM15XA 0XAM15XA 072148X0 072148X0 072130X0 15mt 072131X0 25mt Bollitore Solare 200 lt. 072148X0 300 lt. 072144X0 (per bollitore 200 lt) 072147X0 (per bollitore 300 lt) fi g. 3 (*) Componenti non forniti - Ordinare separatemente Cod.
  • Page 8: Sequenza Di Installazione

    Colonna Solare Multifunzione SEQUENZA DI INSTALLAZIONE MESSA IN SERVIZIO CIRCUITO SOLARE 1 Determinate la posizione di installazione dei componenti. I collettori solari vanno posizionati Il Circuito Solare viene gestito dalla Centralina ECOTRONICH Tech le cui specifi che sono in zona esposta all’irraggiamento solare come riportato nei rispettivi manuali di installazione riportate al cap.
  • Page 9: Manutenzione

    Colonna Solare Multifunzione 1. Prova di tenuta del circuito solare Aprire il dispositivo di sfi ato nel circuito collettori solari (17). Rimuovere i pannelli anteriori del mantello della colonna solare. Aprire il rubinetto di riempimento (1) e quello di svuotamento (11) circuito solare. Applicare un tubo fl...
  • Page 10: Ecotronic Tech

    Colonna Solare Multifunzione 5. ECOTRONIC TECH DATI TECNICI Involucro - plastica, codice materiale: 11439 Bayer INTERFACCIA UTENTE caratteristiche: abs autoestinguente ul-v0 resistente uv 17 18 Tipo di protezione - IP 2 (per la protezione delle persone) IP 20 (per la protezione dell’apparecchiatura) Temp ambiente - funzionamento: -20°c ÷...
  • Page 11: Assegnazione Dei Morsetti

    Colonna Solare Multifunzione ASSEGNAZIONE DEI MORSETTI Sistema Base: Sistema 1 (sistema di default): con 1 serbatoio, 1 circolatore e 2 sonde. con 1 serbatoio, 1 circolatore e 3 sonde. (No circolatore modulante, No contabilizzazione, No riscaldamento integrativo/No smaltimento (Circolatore modulante, Contabilizzazione, No riscaldamento integrativo/No smaltimento calore eccedente).
  • Page 12: Sistema 2A

    Colonna Solare Multifunzione Sistema 2A: Sistema 2B: con 1 serbatoio, 1 circolatore e 3 sonde. con 1 serbatoio, 1 circolatore e 3 sonde. (No circolatore modulante, No contabilizzazione, Con riscaldamento integrativo). (No circolatore modulante, No contabilizzazione, Con smaltimento calore eccedente). - Assegnazione dei morsetti e schema di principio.
  • Page 13: Sistema 3A

    Colonna Solare Multifunzione Sistema 3A: Sistema 3B: con 1 serbatoio, 1 circolatore e 4 sonde. con 1 serbatoio, 1 circolatore e 4 sonde. (Circolatore modulante, Contabilizzazione, Con riscaldamento integrativo). (Circolatore modulante, Contabilizzazione, Con smaltimento calore eccedente). - Assegnazione dei morsetti e schema di principio. - Assegnazione dei morsetti e schema di principio.
  • Page 14: Prima Messa In Funzione

    Colonna Solare Multifunzione PRIMA MESSA IN FUNZIONE 7. FUNZIONAMENTO Il regolatore è impostato di fabbrica come Sistema 1. SISTEMA BASE CON 1 SERBATOIO, 1 CIRCOLATORE E 2 SONDE Per passare ad un altro tipo di Sistema, è possibile modifi care manualmente il parametro (No circolatore modulante, no contabilizzazione, no riscaldamento integrativo/no defi...
  • Page 15: Sistema 1 Con 1 Serbatoio, 1 Circolatore E 3 Sonde

    Colonna Solare Multifunzione Disattivazione Circolatore Solare SISTEMA 1 CON 1 SERBATOIO, 1 CIRCOLATORE E 3 SONDE (Circolatore modulante, contabilizzazione, no riscaldamento integrativo/no smaltimento Se la temperatura del Sensore Bollitore S2 è minore del valore del parametro Temperatura calore eccedente) massima serbatoio (Parametro installatore, di default pari a 60°C) e se la differenza (in positivo) tra la temperatura del Sensore Collettore Solare S3 e la temperatura del Sensore Accensione Ritorno Collettore Solare S4 è...
  • Page 16: Sistema 2A E 2B Con 1 Serbatoio, 1 Circolatore E 3 Sonde

    Colonna Solare Multifunzione SISTEMA 2A E 2B CON 1 SERBATOIO, 1 CIRCOLATORE E 3 SONDE SISTEMA 3A E 3B CON 1 SERBATOIO, 1 CIRCOLATORE E 4 SONDE (No circolatore modulante, No contabilizzazione, Con riscaldamento integrativo) x Schema 2A (Circolatore modulante, Contabilizzazione, Con riscaldamento integrativo) X SCHEMA 3A (No circolatore modulante, No contabilizzazione, Con smaltimento calore eccedente) x Schema 2B (Circolatore modulante, Contabilizzazione, Con smaltimento calore eccedente) X SCHEMA 3B Accensione...
  • Page 17: Modalità Comuni A Tutti I Sistemi Gestiti Dal Regolatore Ecotronic Tech

    Colonna Solare Multifunzione segnalare questa modalità, verrà acceso sempre il simbolo E. MODALITÀ COMUNI A TUTTI I SISTEMI GESTITI DAL REGOLATORE ECOTRONIC TECH Disattivazione Circolatore Solare Modalità off Se la temperatura del Sensore Bollitore S2 è minore del valore del parametro Temperatura In assenza di anomalie o meno, premendo per 3 secondi il tasto ON/OFF é...
  • Page 18: Funzione Temperatura Limite Bollitore

    Colonna Solare Multifunzione di default pari a 80°C) allora il regolatore ECOTRONIC tech lascia attiva il Circolatore Solare Sistema 2: con 1 serbatoio, 1 circolatore e 3 sonde. per prevenire surriscaldamenti del collettore solare. (No circolatore modulante, No contabilizzazione, Con inserimento/disinserimento Se la temperatura del Sensore Bollitore S2 diverrà...
  • Page 19: Anomalie

    Colonna Solare Multifunzione risolta l’anomalia, è possibile rimuovere la protezione attivando e disattivando 8. ANOMALIE la modalità OFF. Display LCD spento Verifi care che il parametro P25 sia impostato correttamente. Verifi care che il Regolatore sia alimentato elettricamente: tramite un multimetro digitale, Caratteristica sensori verifi...
  • Page 20 Colonna Solare Multifunzione Codice anomalia Sch. Descrizione Parametri Trasparenti Range Default Temperatura disinserimento termostato 0–95°C 45°C Codice anomalia (°C) Codice anomalia Parametro bilancio quantità termica (0=Off, 0–1 0=Off Codice anomalia 1=On) Codice anomalia Portata massima circuito solare (l/min) 0–20 6 l/min Codice anomalia Non implementato Codice anomalia...
  • Page 21: Bilancio Quantità Termica (Contabilizzazione)

    Colonna Solare Multifunzione 10. BILANCIO QUANTITÀ TERMICA (CONTABILIZZAZIONE) Il Regolatore esegue il calcolo dell’energia accumulata solo nel caso in cui il Circolatore Solare sia in funzione: il valore viene poi visualizzato attraverso il parametro BIL nel menù History, vedi paragrafo Menù Service. ATTENZIONE: Questa funzione è...
  • Page 22 Le condizioni di garanzia convenzionale qui elencate sono le uniche offerte da Ferroli Spa. Nessun terzo è autorizzato a modifi care i termini della presente garanzia né a rilasciarne altri verbali o scritti.
  • Page 23 Multifunction Solar Column INSTRUCTIONS ..................... 24 CONTENTS 1. INTRODUCTION ....................24 2. INSTALLATION ....................24 IMPORTANT ...................................24 CONNECTION DIAGRAMS ............................26 INSTALLATION SEQUENCE ............................29 3. COMMISSIONING ..................... 29 CALCULATION OF QUANTITY OF SOLAR FLUID FOR FILLING THE SYSTEM............29 SOLAR CIRCUIT COMMISSIONING ..........................29 4.
  • Page 24: Instructions

    fl oor in case of overpressure in the circuit. Thank you for choosing a FERROLI multifunction solar column featuring advan- Otherwise, if the discharge valve cuts in and fl oods the room, the manufacturer ced design, cutting-edge technology, high reliability and quality construction cannot be held liable.
  • Page 25 Multifunction Solar Column One of the following boxes of accessories and fi ttings is supplied with the ECOTOP VRF forced solar system: 072226X0 (for 200-litre hot water tank and 1 ECOTOP VRF) 072225X0 (for 300-litre hot water tank and 2 ECOTOP VRF) 072224X0 (for 300 or 500-litre hot water tank and 3 ECOTOP VRF) (x2) Fit the O-rings “6”...
  • Page 26: Connection Diagrams

    Multifunction Solar Column CONNECTION DIAGRAMS The following drawings give the connection diagrams for the elements contained in the system. Refer to the part codes given on the single packs. (fi g. 2) Diagram with ECOTOP VF fl at collectors 0XCK2RXA 0XCK2RXA 0XCK2RXA 072148X0 (*)
  • Page 27 Multifunction Solar Column One of the following boxes of accessories and fi ttings is supplied with the ECOTUBE forced solar system: 072195X0 (for 200-litre hot water tank) 072196X0 (for 300-litre hot water tank) Install and connect the components as indicated in the diagram. The components indicated with “ ”...
  • Page 28 Multifunction Solar Column Diagram with ECOTUBE vacuum collectors 0XAM15XA 0XAM15XA 072148X0 072148X0 072130X0 15mt 072131X0 25mt Solar Boiler 200 lt. 072148X0 300 lt. Solar Column 072144X0 0XBM2BX0 (boiler 200 lt) 072147X0 (boiler 300 lt) fi g. 3 (*) Components not supplied - Order separately Cod.
  • Page 29: Installation Sequence

    Multifunction Solar Column INSTALLATION SEQUENCE SOLAR CIRCUIT COMMISSIONING 1 Establish the installation position for the components. The solar collectors must be positioned The Solar Circuit is managed by the ECOTRONICH Tech Controller whose in an area exposed to the sun, as given in the respective installation and use manuals. The details are given in chap.
  • Page 30: Maintenance

    Multifunction Solar Column 1. Solar circuit tightness test Open the vent device in the solar collector circuit (17). Remove the front panels of the solar column casing. Open the solar circuit fi lling cock (1) and drain cock (11). Fit a fl exible tube from the cock (11) to the container (10) and from the pump L/min (16) to the cock (1).
  • Page 31: Ecotronic Tech

    Multifunction Solar Column 5. ECOTRONIC TECH TECHNICAL DATA Enclosure - plastic, material code: 11439 Bayer USER INTERFACE characteristics: self-extinguishing abs ul-v0 uv resistant 17 18 Protection type - IP 2 (for protection of people) IP 20 (for protection of equipment) Room temp - operation: -20°C ÷...
  • Page 32: Assigning Of Terminals

    Multifunction Solar Column ASSIGNING OF TERMINALS Basic System: System 1 (default system): with 1 tank, 1 circulating pump and 2 probes. with 1 tank, 1 circulating pump and 3 probes. (No modulating circulating pump, No calculation, No supplementary hea- (Modulating circulating pump, Calculation, No supplementary heating/No elimination of excess heat).
  • Page 33: System 2A

    Multifunction Solar Column System 2A: System 2B: with 1 tank, 1 circulating pump and 3 probes. with 1 tank, 1 circulating pump and 3 probes. (No modulating circulating pump, No calculation, With supplementary (No modulating circulating pump, No calculation, With elimination of excess heating).
  • Page 34: System 3A

    Multifunction Solar Column System 3A: System 3B: with 1 tank, 1 circulating pump and 4 probes. with 1 tank, 1 circulating pump and 4 probes. (Modulating circulating pump, Calculation, With supplementary heating). (Modulating circulating pump, Calculation, With elimination of excess heat).
  • Page 35: First Startup

    Multifunction Solar Column FIRST STARTUP 7. OPERATION The regulator is factory-set as System 1. BASIC SYSTEM WITH 1 TANK, 1 CIRCULATING PUMP AND 2 PROBES To go to another type of System, it is possible to manually modify the pa- (No modulating circulating pump, no calculation, no supplementary rameter defi...
  • Page 36: System 1 With 1 Tank, 1 Circulating Pump And 3 Probes

    Multifunction Solar Column the fi rst second of operation. SYSTEM 1 WITH 1 TANK, 1 CIRCULATING PUMP AND 3 PROBES (Modulating circulating pump, calculation, no supplementary heating/no If the Solar Circulating Pump Operation parameter (Installer parameter, elimination of excess heat) default value equal to 1=Modulating) is set to 0 there will be no modulation: the Solar Circulating Pump will work in on/off mode according to the normal Switching on...
  • Page 37: System 2A And 2B With 1 Tank, 1 Circulating Pump And 3 Probes

    Multifunction Solar Column (Installer parameter, default value equal to 40°C) then the ECOTRONIC SYSTEM 2A AND 2B WITH 1 TANK, 1 CIRCULATING PUMP AND 3 PROBES tech regulator activates the output Relay connected to terminals 13-14-15 (No modulating circulating pump, No calculation, With supplementary heating) for (FREE CONTACT on the 11-pin connector);...
  • Page 38: System 3A And 3B With 1 Tank, 1 Circulating Pump And 4 Probes

    Multifunction Solar Column differential parameter value (Installer parameter, default value equal to 5°C), the SYSTEM 3A AND 3B WITH 1 TANK, 1 CIRCULATING PUMP AND 4 PROBES Solar Circulating Pump works at speed 5 (Max. power, 100%). (Modulating circulating pump, Calculation, With supplementary heating) for To signal this mode, the symbol E will be lit.
  • Page 39: Mode Common To All Systems Managed By The Ecotronic Tech Regulator

    Multifunction Solar Column Water Tank Cooling Function. MODE COMMON TO ALL SYSTEMS MANAGED BY THE ECOTRONIC TECH REGULATOR During normal operation, if the temperature of Hot Water Tank Sensor Off mode If there are no faults it is always possible to press the ON/OFF button for 3 S2 is higher than the Tank max.
  • Page 40: Solar Circulating Pump Anti-Shutdown Function

    Multifunction Solar Column Solar Circulating Pump Anti-shutdown function System 2: with 1 tank, 1 circulating pump and 3 probes. After 24 hours of inactivity, the Solar Circulating Pump is activated for 3 (No modulating circulating pump, No calculation, With Boiler activa- seconds.
  • Page 41: Faults

    Multifunction Solar Column detect fl ow rate in the solar circuit for 10 consecutive minutes. 8. FAULTS The fault causes deactivation of the Solar Pump. After checking and elimina- LCD display off ting the fault, the protection can be removed, activating and deactivating the Off mode.
  • Page 42 Multifunction Solar Column Fault code Dia- Description of Transparent Parameters Range Default gram Fault code Antifreeze liquid protection rating (%) 0-50% Fault code Solar Circulating Pump output operation 1=Auto Fault code mode Fault code (0=OFF continuous, 1=auto and 2=ON No. hours Solar Circulating Pump between 0 and 9999 hours continuous) operation...
  • Page 43: Thermal Quantity Balance (Calculation)

    Multifunction Solar Column 10. THERMAL QUANTITY BALANCE (CALCULATION) The regulator performs the accumulated energy calculation only if the Solar Circulating Pump is working: the value is then displayed through the para- meter BIL in the History menu, see section on Service Menu. ATTENTION: This function depends on the value of parameter P15 Thermal Quantity Balance (Installer parameter, default value equal to 0=Off) which must be set to 1.
  • Page 44 Colonne solaire multifonction TABLES DES MATIÈRES AVERTISSEMENT ..........................45 1. INTRODUCTION ..........................45 2. INSTALLATION ..........................45 AVERTISSEMENTS ........................................ 45 SCHÉMAS DE BRANCHEMENT .................................... 47 SÉQUENCE D'INSTALLATION ....................................50 3. MISE EN SERVICE ........................50 CALCUL DE LA QUANTITÉ DE FLUIDE SOLAIRE POUR LE REMPLISSAGE DE L'INSTALLATION ..............50 MISE EN SERVICE DU CIRCUIT SOLAIRE ................................
  • Page 45: Avertissement

    072130X0 (15 mt) ou 072131X0 (25 mt). Compte tenu des températures élevées que le fl uide Nous vous remercions d'avoir choisi une colonne solaire multifonction FERROLI, de conception caloporteur peut atteindre, l'utilisation de tuyaux en plastique, par exemple, des tuyaux en PE ou avancée, de technologie d'avant-garde, de fi...
  • Page 46 Colonne solaire multifonction Le système solaire forcé ECOTOP VRF dispose également d’une des boîtes d’accessoires et de raccords suivantes: 072226X0 (pour ballon 200 l et 1 ECOTOP VRF) 072225X0 (pour ballon 300 l et 2 ECOTOP VRF) 072224X0 (pour ballon 300 ou 500 l et 3 ECOTOP VRF) (x2) Monter les joints toriques “6”...
  • Page 47: Schémas De Branchement

    Colonne solaire multifonction SCHÉMAS DE BRANCHEMENT Les dessins sous-jacents indiquent les schémas de branchement entre les éléments contenus dans le système. Faire référence aux codes des composants indiqué sur les emballages. (fi g. 2) Schéma avec collecteurs plats ECOTOP VRF 0XCK2RXA 0XCK2RXA 0XCK2RXA...
  • Page 48 Colonne solaire multifonction Les système solaire forcé ECOTUBE dispose également d’une des boîtes d’accessoires et de raccords suivantes: 072195X0 (pour ballon 200 l) 072196X0 (pour ballon 300 l) Installer et raccorder les composants comme le montre le schéma. Les composants marqués “ ”...
  • Page 49 Colonne solaire multifonction Schéma avec collecteurs sous vide ECOTUBE 0XAM15XA 0XAM15XA 072148X0 072148X0 072130X0 15mt 072131X0 25mt Ballon Solaire 072148X0 200 lt 300 lt Colonne Solaire 072144X0 0XBM2BX0 (pour ballon 200 lt) 072147X0 (pour ballon 300 lt Fig. 3 (*) Composants non fournis - Commander séparément Cod.
  • Page 50: Séquence D'installation

    Colonne solaire multifonction SÉQUENCE D'INSTALLATION MISE EN SERVICE DU CIRCUIT SOLAIRE 1. Défi nir la position d'installation des composants Les collecteurs solaires doivent être posi- Le circuit solaire est géré par l'unité de commande ECOTRONICH Tech dont les spécifi cations tionnés dans une zone exposée au rayonnement solaire comme indiqué...
  • Page 51: Entretien

    Colonne solaire multifonction 1. Essai d'étanchéité du circuit solaire Ouvrir le purgeur du circuit des collecteurs solaires (17 - ) Ôter les panneaux avant de l'habillage de la colonne solaire. Ouvrir le robinet de remplissage (rep. 1 - ) et celui de vidange (rep. 11 - ) du circuit solaire Appliquer un tuyau fl...
  • Page 52: Ecotronic Tech

    Colonne solaire multifonction 5. ECOTRONIC TECH CARACTÉRISTIQUES TECHNIQUES Habillage - plastique, code matériel : 11439 Bayer INTERFACE USAGER caractéristiques : abs auto-extinguible ul-v0 résistant uv 17 18 Type de protection - IP 2 (pour la protection des personnes) IP 20 (pour la protection de l'appareil) Temp ambiante - mode de fonctionnement : -20°c ÷...
  • Page 53: Bornage

    Colonne solaire multifonction BORNAGE Système Base : Système 1 (système par défaut): avec 1 réservoir, 1 circulateur et 2 sondes. avec 1 réservoir, 1 circulateur et 3 sondes. (pas de circulateur modulant, pas de comptabilisation, pas de chauffage auxiliaire/pas (Circulateur modulant, Comptabilisation, Pas chauffage auxiliaire/ pas évacuation chaleur d'évacuation de la chaleur en excès).
  • Page 54: Système 2A

    Colonne solaire multifonction Système 2A : Système 2B : avec 1 réservoir, 1 circulateur et 3 sondes. avec 1 réservoir, 1 circulateur et 3 sondes. (Pas circulateur modulant, Pas Comptabilisation, avec chauffage auxiliaire). (Pas circulateur modulant, Pas Comptabilisation, avec évacuation chaleur en excédent). - Bornage et schéma de principe.
  • Page 55: Système 3A

    Colonne solaire multifonction Système 3A : Système 3B : avec 1 réservoir, 1 circulateur et 4 sondes. avec 1 réservoir, 1 circulateur et 4 sondes. (Circulateur modulant, Comptabilisation, avec chauffage auxiliaire). (Circulateur modulant, Comptabilisation, avec évacuation chaleur en excédent). - Bornage et schéma de principe. - Bornage et schéma de principe.
  • Page 56: Première Mise En Fonction

    Colonne solaire multifonction PREMIÈRE MISE EN FONCTION 7. FONCTIONNEMENT Le régulateur est programmé d'usine comme système 1. SYSTÈME BASE AVEC 1 RÉSERVOIR, 1 CIRCULATEUR ET 2 SONDES Pour passer à un autre type de système, il est possible de modifi er manuellement le paramètre (Pas circulateur modulant, Pas Comptabilisation, Pas chauffage auxiliaire/pas éva- défi...
  • Page 57: Système 1 Avec 1 Réservoir, 1 Circulateur Et 3 Sondes

    Colonne solaire multifonction Désactivation circulateur solaire SYSTÈME 1 AVEC 1 RÉSERVOIR, 1 CIRCULATEUR ET 3 SONDES ( Circulateur modulant, Comptabilisation, Pas chauffage auxiliaire/pas évacuation Si la température du capteur ballon S2 est inférieure à la valeur du paramètre température chaleur en excédent) maximum réservoir (Paramètre installateur, par défaut 60°C) et si la différence (positive) entre la température du capteur collecteur solaire S3 et la température du capteur retour Allumage...
  • Page 58: Système 2A Et 2B Avec 1 Réservoir, 1 Circulateur Et 3 Sondes

    Colonne solaire multifonction SYSTÈME 2A ET 2B AVEC 1 RÉSERVOIR, 1 CIRCULATEUR ET 3 SONDES SYSTÈME 3A ET 3B AVEC 1 RÉSERVOIR, 1 CIRCULATEUR ET 4 SONDES (Pas de circulateur modulant, Pas de Comptabilisation, avec chauffage auxiliaire ) x Schéma 2A (Circulateur modulant, Comptabilisation, avec chauffage auxiliaire) X SCHÉMA 3A (Pas de circulateur modulant, Pas de Comptabilisation, avec évacuation chaleur en excédent ) x (Circulateur modulant, Comptabilisation, avec évacuation chaleur en excédent) X SCHÉMA 3B...
  • Page 59: Désactivation Circulateur Solaire

    Colonne solaire multifonction signaler cette modalité, le symbole E sera allumé en permanence. MODALITÉS COMMUNES À TOUS LES SYSTÈMES GÉRÉS PAR LE RÉGULATEUR ECOTRONIC TECH Désactivation circulateur solaire Si la température du capteur ballon S2 est inférieure à la valeur du paramètre température Mode OFF maximum réservoir (Paramètre installateur, par défaut 60°C) et si la différence (positive) En absence d'anomalie, en appuyant 3 secondes les touches ON/OFF il est toujours possible...
  • Page 60: Fonction Température Limite Ballon

    Colonne solaire multifonction inférieure à la valeur du paramètre température limite ballon (paramètre installateur, par Système 2: avec 1 réservoir, 1 circulateur et 3 sondes. défaut 80°C) alors le régulateur ECOTRONIC tech laisse le circulateur solaire activé pour (Pas circulateur modulant, Pas Comptabilisation, avec activation/désactivation prévenir les surchauffes du collecteur solaire.
  • Page 61: Anomalies

    Colonne solaire multifonction La panne provoque la désactivation de la pompe solaire. Une fois identifi ée et 8. ANOMALIES résolue l'anomalie, il est possible de RAZ la protection en activant et désacti- Affi cheur LCD éteint vant le mode OFF. Vérifi...
  • Page 62 Colonne solaire multifonction Code anomalie Fiche Description Paramètres Transparents Plage Défaut Paramètre bilan quantité thermique (0=Off, 0–1 0=Off Code anomalie 1=On) Code anomalie Puissance maximum circuit solaire (l/min) 0–20 6 l/min Code anomalie Non prévu Code anomalie Degré de protection liquide antigel (%) 0-50% Code anomalie Modalité...
  • Page 63: Bilan Quantité Thermique (Comptabilisation)

    Colonne solaire multifonction 10. BILAN QUANTITÉ THERMIQUE (COMPTABILISATION) Le régulateur effectue le calcul de l'énergie accumulée uniquement si le circulateur solaire fonctionne : la valeur est visualisée via le paramètre BIL sur le menu History, voir paragraphe Menu Service. ATTENTION : Cette fonction est subordonnée à...
  • Page 64 FERROLI S.p.A. - Via Ritonda 78/a - 37047 San Bonifacio (Verona) Italy - tel. +39.045.6139411 - fax. +39.045.6100933 - www.ferroli.it...

Table des Matières