Fault
Water flows conti-
nuously
Water too hot
Water too cold
Water volume too low
Thermostat controls
unevenly
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department!
Cause
– Solenoid valve cartridge faulty
– Flow rate regulator in shower head
blocked with scale
– Scald protection set incorrectly
– Thermal element faulty
– Scald protection set incorrectly
– Hot water flow blocked
– Dirty filters/non-return valves
– Hot water supply pressure too low
– Hot water temperature too low
– Thermal element faulty
– Water volume regulator not fully open
– Shower head blocked with scale
– Dirty filters/non-return valves
– Supply pressure too low
– Flow rate regulator in shower head
blocked with scale
– Thermal element dirty
- 17 -
Remedy
➯ Replace it
➯ Clean and
replace if
necessary
➯ Set it
➯ Replace it
➯ Set it
➯ Open it
➯ Clean and
replace if
necessary
➯ Check it
➯ Increase it
➯ Replace it
➯ Open it
➯ Clean it
➯ Clean and
replace if
necessary
➯ Check it
➯ Clean and
replace if
necessary
➯ Clean it