Attention!
The emitter point must be situated 0.8 mm below the nozzle tip.
10.2. Replacing the valve
1. Disconnect the compressed air supply.
2. Remove the trigger pin (properly support the trigger).
3. Remove the trigger.
4. Unscrew the valve from the gun.
5. Screw the new valve into the gun.
6. Place the trigger.
7. Fit the trigger pin.
When replacing the HV cable, it is recommended to send the gun for repair to SIMCO
(Nederland) B.V.
Pack it properly and clearly state the reason for return.
11. Disposal
Adhere to the applicable local environmental and other rules when disposing of the equipment.
12. Spare parts
65.05.04.0310
65.05.04.0300
65.00.21.0003
65.05.04.0220
65.05.04.0200
65.05.04.0210
65.05.04.0110
02.06.00.0000
35.05.00.0010
ES-2J_UM_9752050510_NL_D_GB_F_V2_0
Complete gun tip
Nozzle tip
Nozzle tip insert
Valve
Trigger
Trigger pin
Gun housing cover
Bar checker
Spanner and spacer ring for emitter point adjustment
20