Note:
The modes of DMX 512 data and lamp are shown via the display:
1. After switching on, the device will automatically detect whether DMX 512 data is received or not. If the
data is received, the the display will show "A.001" with the actually set address. If there is no data received
at the DMX-input, the display will flash "A001" with the actually set address.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.
Note:
It's necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to
ensure proper transmission on the DMX data link.
2. If the lamp is on, the the display will show "A00.1" with the actually set address. If the lamp is off, the the
display will show "A001" with the actually set address.
44/111
00025097.DOC,Version 1.7