Columns
*
Omission or use of incorrect snowstorm filling devices.
*
Excessive exposure of desiccant to atmosphere during filling.
*
Hand filling or 'topping up' without correct filler.
*
Leaving desiccant media in bolt holes when torquing down top manifold bolts.
*
Failure to remove all desiccant from column during desiccant change.
Top Manifold/Outlet Valve
*
Incorrect torquing of column bolts - sequence tightening must be employed.
*
Use of non-AR TS dust filters on DH Models.
*
Cleaning of column bolts before torquing.
*
Faulty torque setting.
*
Use of incorrect wire stripping tools.
Control Box
*
Excessive voltage drop on incoming supply.
*
Purge setting by amps, non-use of flow meters.
*
Incorrect fusing used (external).
*
Incorrect supply wire (incoming).
*
No earth wire between earth terminal and armour cable clamp on shroud.
*
Manually turning cam timer backwards.
Additional Items
*
Use of non-recommended desiccant or non-genuine domnick hunter spare parts from alternative suppliers.
*
Servicing undertaken by untrained distributor personnel.
*
Inability to maintain inlet pressure and temperature at levels stated for sizing.
*
Not to use dryer/dryers if piped directly after a portable compressor.