Known Misuse - Domnick Hunter PNEUDRI DX102 Manuel D'installation, De Mise En Service Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

F) Known Misuse
(Please ensure that the following do not occur in your installation)
Inlet Filters
*
Installation of filters remote from dryer allowing further condensation to occur between filters and the dryer.
*
Blow down valve upstream of filters causing back flow/possible collapse of filter element.
*
Installing AO/AA filters in wrong flow direction.
*
Opening inlet valve too quickly, causing initial high Differential Pressure across filter element.
*
Differential Pressure gauge fitted wrong way round giving false Differential Pressure indication.
*
Combining drain pipes from a water Separator and AO/AA.
Inlet Manifold
*
Pipe diameter too small, causing preferential flow on multi-bank installations.
*
No automatic drains fitted to pipework.
*
Unsupported pipework causing strain on gasket joints.
*
Not enough clearance for removing filter bowls.
*
Pipework from manifold to dryer taken from the bottom of the manifold instead of the top or centre allowing bulk
water to drain into dryer inlet.
Lower Manifold
*
Pipe kinks to control valves causing poor/non-response - use of too short pipes.
*
Insufficient room to remove inlet valve assembly.
*
Insufficient room to remove exhaust valve assembly.
INLET
MANIFOLD
TO DRYER
INLET
MANIFOLD
TO DRYER
either way is ok
33

Publicité

Table des Matières
loading

Table des Matières