With the mode selector dial, adjust the heater to suit your preferences: fan only,
low power (EK15002: average power) or high power.
Once the temperature in the area being heated has reached the right level, slowly
turn the thermostat dial anticlockwise until you hear a soft click; leave the dial in
that position. The heater will automatically maintain the temperature at this level.
It does this by switching the heating elements off and on when the temperature
rises or falls too much.
If so desired, you can now switch to a lower power level.
To switch off, turn the power switches to O (off). The heater switches off. Unplug.
Note! After the thermostat has switched the heating elements off, the fan will keep
turning. This means that the air is constantly moved, allowing the heater to
accurately detect if the area is cooling down.
The thermostat dial is continuously adjustable. A higher temperature is set by
turning it clockwise; a lower temperature by turning it anticlockwise.
Model EK 9002 & 15002 is fitted with an extra feature to increase safety and the
life span of the device.
This extra feature only switches the ventilator of the fan off when the temperature
in the heater has dropped below 30 degrees Celsius. When you switch the heater
off by switching the function button to 0, the ventilator continues to operate for 3
to 4 minutes until the temperature in the heater has dropped below 30 degrees
Celsius. You may only remove the plug from the socket when the ventilator is
completely stopped.

Safety features

In case of internal overheating, the overheating safeguard will switch the heater
off. If this occurs, immediately turn the mode selector dial to O, unplug and allow
heater to cool down for at least 10 minutes. The EK9002 and EK15002 require
resetting now by inserting a pen into the small reset hole on the operating panel. In
theory, the heater can now be used as normal.
There is, however, generally a reason for an appliance overheating. This may be
because the heater cannot adequately release its heat or take in fresh air (because
the heater is covered, the grills are blocked, the heater is placed too near a wall
etcetera). Before using the heater again, therefore, remove or adjust whatever
caused the appliance to overheat. If you cannot find the cause and overheating
recurs, stop using the heater and contact your vendor or a certified electrician for
inspection/repair. Overheating poses a serious fire risk!

Cleaning and Maintenance

Keep the heater clean. Deposits of dust and dirt in the appliance are a common
cause of overheating so these should be removed regularly. Switch off the heater,