17
OPTIONAL FEATURES:
Presetting memorized also when machine is switched off:
Presetting Lost when machine is switched off:
Display of unbalance:
Dynamic
S
18
WHEEL BALANCING
MEASUREMENT OF UNBALANCE
-To make a measuring spin, close the guard (alternatively press START if selected)
-In a few seconds the wheel is brought up to speed and a new braking; the amounts of unbalance remain memo-
rized on instruments 1 and 2.
-The illuminated LED display show the correct angular position where to fit the counterweight (12 O'CLOCK posi-
tion)
-In this screen, a light pressing of key "C" will display in sequence the preset dimensions.
Abb.5: POSITIONING AND CORRECTION ON THE OUTSIDE
Abb.5: POSITIONING AND CORRECTION ON THE INSIDE
RECALCULATION OF THE UNBALANCE
-Preset the new dimensions as above procedures instructed.
-Without repeating the spin, press "C"
-The new recalculated unbalance values are displayed.
UNIT of measurement of unbalance grams/ounces
Start with guard closed
UNIT of measurement of width mm/inch
(From "PRESETTING OF DIMENSIONS" by selecting WIDTH)
NOTE: In inches each time machine is switched on.
Unit of measurement of DIAMETER mm/inch
(From "PRESETTING OF DIMENSIONS" by selecting DIAMETER)
NOTE: In inches each time machine is switched on.
Static
1
2
Dynamic
3
S
Abb. 5
23