Annexe
A.1 Aperçu de la structure de commande HART
A-4
5 Mech. Construction
Mech = mechanical
7 Diagnosis/Service
1 Status
2 Device
3 Diagnostic settings
4 View
6 Certif & Approv
1 Explos. Protection
Certif=Certification
Explos = Explosion
Approv=Approval
4 LCD Settings
1 LCD Scaling, if On:
5 Bargraph
6 Access Control
1 Lokal keys control mode
2 Write protect
3 Set write protect --> M
1 No of electronic changes
2 Design
1 Sensor
2 Remote Seal
3 Process Connection
1 Process Connection
2 DrainVent / plug mat
3 DrainVent / plug pos
4 Process flange bolt
5 Flange type
6 Flange material
4 Electronic Connection
1 Electr housing material
2 Electr connection
1 Status summary
2 Extended device status
3 Simulation status
4 Hardw/Firmw status
1 Status group 2
2 Status group 3
3 Status group 4
4 Status group 5
5 Diag Alarm Status
1 Status group 15
2 Status group 16
6 Diag Warn Status
1 Status group 19
2 Status group 20
1 Selftest/Reset
1 Selftest --> M
2 Display Test --> M
3 Master reset --> M
4 Changes Config
2 Sensor trim
1 Restore mfgr trims --> M
2 Sensor trim
3 Trim analog output
4 Position correction
3 Simulation/Test
1 Loop test --> M
2 Inputs --> M
4 Access Control
1 Local keys control mode
2 Write protect
3 Set write protect --> M
1 W/A time unit
W/A = warning/alarm
2 Calib interval
1 Calib status
2 W/A acknowledge --> M
3 Calib timer
4 Calib warning
5 Calib alarm
6 W/A activation
3 Service interval
1 Service status
2 W/A acknowledge --> M
3 Service timer
4 Service warning
5 Service alarm
6 W/A activation
4 AO saturation
1 AO alarm type
2 Saturation alarm
3 Alarm duration
4 Alarm activation
5 Limiter setup
1 Display limiter --> M
2 Setup limiter --> M
3 Limiter status --> M
4 Limiter: Ack W/A --> M
5 CmpCnt: Ack W/A --> M
6 Reset counter. --> M
1 Operating hours
1 Operating hours Electr
2 Operating hours Sensor
3 Min/Max pointer
1 Pressure pointer
2 Electr-Temp pointer
3 Sens-Temp pointer
Instructions de service, 06/2005, A5E00359578-02
2 LCD Unit
3 LCD LRV
4 LCD URV
1 Fill fluid
2 Isolation material
3 O ring material
4 Module range
1 Number remote seal (RS)
2 RS type
3 RS isolator material
4 RS fill fluid
5 Extension length
6 Extension type
7 Capillar length
1 Config changed counter
mfgr = manufacturer
1 Sensor trim points
1 Lower sensor trim point
2 Upper sensor trim point
2 Sensor trim
1 Pres zero trim--> M
2 Lower sensor trim --> M
3 Upper sensor trim --> M
3 Trimpoint summary
1 D/A trim --> M
2 Scaled D/A trim --> M
1 Position corr --> M
Simulation AO
Simulation Fixed / Ramp
1 Calib time
2 Reset timer --> M
1 Service time
2 Reset timer --> M
Ack = acknowledge
CmpCnt =
Comparation Counter
1 Pres max
2 Pres min
3 Reset pointer --> M
1 Electr-Temp max
2 Electr- Temp min
3 Reset pointer --> M
1 Sens-Temp max
2 Sens-Temp min
3 Reset pointer --> M
SITRANS P300 avec communication HART