13. What if there are problems?

If the scale encounters an error during measurement, the following is displayed:
Display
Only weight display
P-01 – P-08
and
missing
Incorrect weight is dis-
played.
Incorrect weight is dis-
played.
Incorrect weight is dis-
played.
No Bluetooth
con-
®
nection ( symbol is
missing).
The Bluetooth
word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any
®
use of such marks by Beurer GmbH is under license. Other trademarks and trade names are those of
their respective owners.
Cause
Unknown measurement as
it is outside the user assign-
are
ment limit or a unique assign-
ment is not possible.
The proportion of fat is out-
side the measurable range
(less than 4 % or greater than
65%).
Maximum weight capacity of
180 kg exceeded.
No flat, stable surface.
Not standing still.
Incorrect zero point of scale.
Device outside the range.
No connection to the app.
User memory space is full.
New measurements overwrite
the older measurements.
The batteries in the scale are
empty.
Solution
Select user on the scale using the " " but-
ton or repeat user assignment in the app.
See chapter 10 "Additional information".
Please repeat the measurement barefoot, or
with the soles of the feet lightly dampened if
necessary.
If
is still displayed, you are outside of the
measurable range.
Loads must be limited to 180 kg.
Place the scale on a flat, stable surface.
No carpet.
Stand as still as possible.
Wait until the scale switches itself off. Activate
scale. "C" may be displayed. Wait for "0.0 kg".
Then repeat the measurement.
The range in the open is approx. 15 m. Walls
and ceilings reduce the range.
Other radio waves may interfere with the
transmission. Therefore, do not position the
scale near devices such as WIFI routers,
microwaves, induction hobs etc.
Completely close the app (including in the
background).
Switch Bluetooth
Switch the smartphone off and back on again.
Remove the batteries in the scale for a short
period and reinsert them.
See FAQs at www.beurer.com.
Open the app. The data is transferred auto-
matically. This may take up to one minute.
Replace the batteries in the scale.
22
off and back on again.
®