RHOSS ELECTA Série Mode D'emploi page 69

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Menu parameters list "Set":
Menu parameters list "Set" 1-2
Menù label
Par
Label
100
tbEn
HP
101
MOdE
102
nigH
103
LAn
104
OFSt
105
OFSH
106
AMbt
107
AMbH
108
OUtA
109
OUtU
110
P3-4
SEnS
111
in34
112
SAnt
113
dEUS
Section I :: User
Description
On: Activation of the heat pump On/Off time bands
Off: Deactivation of the heat pump On/Off time bands
Operation mode: Cooling/Heating
0: Change through USER INTERFACE (and KCTR if
installed)
1: Change through external contact "Remote Cool/
Heat", heating mode = open contact
2: Change through external contact "Remote Cool/
Heat", heating mode = closed contact
Compressor maximum work frequency limit
KCTR installation:
On:Installed
Off: Not installed.
Offset on the Room Temperature detected by KCTR
Offset on the Room umiduty detected by KCTR
Room temperature detected by KCTR
Room humidity detected by KCTR
External environment temperature
Temperature of outlet water from heat pump
Supply System), on-SC:
0: STANDARD. Temperature signal from the sensor
on the return water. The connector "In WS" must be
connected to the TERMINAL BLOCK.
1: NTC_RADIANT. Is acquired water temperature to
the radiant system (sensor properly positioned by the
installer). The connector "In WS" must be disconnected
from TERMINAL BLOCK.
2: NTC_TANK. Is acquired temperature of inertial system
accumulation for the advanced management of an
additional generator (sensor properly positioned by the
installer). The connector "In WS" must be disconnected
from TERMINAL BLOCK (see Appendices "Advanced
Management additional generator").
3: Not used.
Temperature-signal input "Temp Water Supply
System "(terminals 3-4):
- If P3-4 = 0: return water temperature to the PdC
- If P3-4 = 1: water temperature at the outlet of the
radiant system
- If P3-4 = 2: the water temperature on the
accumulation, placed between the heat generators
and users
- If P3-4 = 3: not used
State-temperature value storage tank, input "Sanitary
Water Tank Sensor" (terminals 5-6):
0.0 = contact open
0.1 = contact closed
Input State Dew Point Sensor (terminals IN-COM):
On = closed contact. Moisture above the limit
Off = open contact. Humidity below the limit
Range
U.m .
min
-
Off
-
0
%
Min
-
Off
°C
-5
°C
-10
°C
-
°C
-
°C
-
°C
-
-
0
°C
-
°C
-
-
-
X=Parameter also available on KCTR
69
Default KCTR
PW
max
On
Off
2
2
S
100
50
On
S
5
0
S
10
0
S
Read
-
Value
Read
-
Value
Read
-
Value
Read
-
X
Value
3
0
S
Read
-
Value
Read
-
Value
Read
-
Value
S = Password service (48)
EN
Address
16465
16386
16388
16390
16412
16468
8972
8973
8974
8975
16389
8969
8976
8977