Cabinet Dimensions
IMPORTANT: If installing a range hood or microwave hood
combination above the cooktop, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
C
K
A. Minimum upper cabinet width. See the "Standard Install Dimensions"
table.
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform
and bottom of uncovered wood or metal cabinet (24" [61.0 cm]
minimum clearance if bottom of wood or metal cabinet is covered
by not less than 1/4" [0.06 mm] flame retardant millboard covered
with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper cabinet depth
E. 2
/
" (5.9 cm) minimum distance to front countertop edge
5
6
F. 20
/
" (51.8 cm)
3
8
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cooktop
H. Junction box or outlet: 7" (17.8 cm) minimum from top of countertop
I. Junction box or outlet: 9" (23.0 cm) maximum from right side of
cabinet
J. See the "Standard Install Dimensions" Table
K. 6" (15.2 cm) minimum side wall clearance
L. 2
/
" (5.9 cm) minimum distance to rear combustible surface
5
16
4
A
D
B
L
F
E
H
I
J
Standard Install Dimensions Table
NOTE: When pairing cooktops, this option is recommended only
with stainless steel or framed cooktops.
Units
One 15" (38.1 cm) unit
Two 15" (38.1 cm) units
Three 15" (38.1 cm) units
Four 15" (38.1 cm) units
24" (61.0 cm) cooktop
G
24" (61.0 cm) cooktop and
one 15" (38.1 cm) unit
24" (61.0 cm) cooktop and
two 15" (38.1 cm) units
30" (76.2 cm) cooktop
30" (76.2 cm) cooktop and
one 15" (38.1 cm) unit
30" (76.2 cm) cooktop and
two 15" (38.1 cm) units
36" (91.4 cm) cooktop
36" (91.4 cm) cooktop and
one 15" (38.1 cm) unit
NOTE: After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
If cabinet has a drawer, a 5
the countertop to the top of the drawer (or other obstruction)
in base cabinet is required.
Flush Installation Dimensions
All cooktops can be mounted with a frameless standard
installation sitting on top of the countertop surface or flush with
the top of the countertop.
If the cooktop is to be mounted flush with the countertop, a
recessed area surrounding the cooktop cutout must be provided
with the following dimensions:
1. 11/64" (4.3 mm) recessed depth is needed for the SS Frame
Model (see dimension E).
2. 7/32" (5.6 mm) recessed depth is needed for the Glass
Model without a frame.
NOTE: This option is not recommended for countertops with
a molded backsplash. Do not silicone seal in place.
Upper Cabinet
Cutout
Width (A)
Width (J)
15"
14
(38.1 cm)
(36.5 cm)
30"
29
(76.2 cm)
(74.6 cm)
45"
44
(114.3 cm)
(112.9 cm)
60"
59
(152.4 cm)
(151.0 cm)
24"
22
(61.0 cm)
(58.3 cm)
39"
38
(99.1 cm)
(97.0 cm)
54"
53
(137.2 cm)
(135.6 cm)
30"
28
(76.2 cm)
(73.6 cm)
45"
44
(114.3 cm)
(112.2 cm)
60"
59
(152.4 cm)
(150.3 cm)
36"
34
(91.4 cm)
(88.8 cm)
51"
50
(129.5 cm)
(127.5 cm)
/
" (14.0 cm) depth clearance from
1
2
/
"
3
8
/
"
3
8
/
"
7
16
/
"
7
16
/
"
31
32
/
"
3
16
/
"
3
8
/
"
31
32
/
"
3
16
/
"
3
16
/
"
31
32
/
"
3
16