of the plant it's necessary to install the pump under the level of the chemical, you
♦
need to use an injection valve or an anti siphon valve.
Do not install the pump over the tank in presence of liquids that emanate fumes
♦
unless it
is hermetically closed.
♦
2.2 Electrical characteristics
Power supply: 230 VAC 50/60 HZ
2.3 Standard Kit
1. Technopool pump
2. Suction and delivery tubing
3. Buffer solutions pH4-pH7-Rx
4. Fixing slide clamp
5. Wall fixing screws
i. pH – Rx probe
j. 2 Electrodes holder
k. 2 Collars DN50
g. 2 Injection nipples
h. 2 Collars DN50
f. 2 Suction filters
m. 2 closing washer for calibration
2.4 Hydraulic Connection
2.5 Electric connection
Before installation ensure that the supply is adequately earthed and is fitted with a suitably
sensitive circuit breaker. Connect the pump to the power supply respecting the values you
can see on the identify label of the pump.
The power supply cable "b" is connected to the junction box "m" (must be 230v) on
auxiliary contact linked at the main pool circulation pump "n", or in parallel at A1 and A2 of
pool circulation pump contactor coil.
TECHNOPOOL PH-RX
1
Rx