3.2.10 Manual Functioning
With this sub-menu the Technopool can be programmed to dose without external signal for
a certain time, programming the percentage of manual functioning of pH and Rx pump
(percentage of 5 minutes cycle ) and the duration .
When the period of Manual Functioning is over the system goes back to reading/working
mode.
3.2.11 Clock Settings
This function is available only on CONNECT model
3.2.12 Buzzer setting
The Technopool is equipped with a Buzzer that can underline each condition of alarm
3.2.13 Relay settings
The Technopool is equipped with an additional free - voltage relay output that can be used
as follow:
Alarm Repetition (it can be set Open or Closed with alarm)
♦
Output for Salt Chlorinator of additional chlorine pump (Up to 5A 230V 50Hz) in this
♦
case the relé is driven by an additional set point. (It can be Open or Closed Below
mV set point).
A-TECHNOPOOL PH-RX
28/06/2010
11/64