Cold water
Water pressure
Water hardness
Position of water connection
m m
8 0
"
3 ⅛
IG 1/2"
Pre-installation
> Install the water connection and water outlet in the
specified areas.
Health risk and potential product
WARNING
damage!
> Supply the integrated shower toilet with tab water
from the main water system.
> Do not connect any waste water, grey water, industrial
water, sea water or other untreated or semi-treated
water.
Risk of product damage due to hard
NOTICE
water.
> Install a water softener with water hardness
≥ 2.4 mmol/l (≥ 240 ppm).
DN 15(½" NPS)
0.07 – 0.75 MPa
(10 – 109 psi)
max. 2.4 mmol/l
(240 ppm)
2
Positioning the mounting template
> Position the mounting template.
> Ensure that the position of the drainage hole, the
inlet water supply pipe hole correspond to the
dimensional drawing and the mounting template.
> Ensure that the line designating the center of the
mounting template is the same line designating
the center of the drainage hole.
16
Preparing the inlet hose adaptor
> Put watertight material around one end of the
inlet hose adaptor.
26
Connecting water
NOTICE
Avoiding any malfunctions!
> The new hose-sets supplied with the appliance
are to be used and old hose-sets should not be
reused.
31
Opening the stop valve
> Open the main water supply.
> Open the stop valve.
> Flush the water supply hose and collect water.
> Close the main water supply.
35
Checking for leaks
> Open the water supply.
> Check if there is any water leakage.
> Close the water supply.