Operating the generator
8.6

Display messages

Display message
Description
LOW BATTERY
The battery voltage has fallen
below the minimum value for
starting up (9 V).
OIL CHANGE
The number of prescribed oper-
ating hours has been reached for
changing the engine oil.
NO FUEL
The fuel in the tank is in reserve.
OIL ALERT
Insufficient engine oil.
GENERATOR ALERT!
General alarm message
Example: The control ring on the
throttle valve of the carburettor
(stepper motor) is faulty.
OVERLOAD!
The consumers generate an
overload at the output.
SHORT CIRCUIT
The consumers cause a short cir-
cuit at the output.
OVER TEMPERATURE
Overheating
LOW POWER ENGINE
The inverter supply voltage has
dropped.
20
Generator behaviour
The generator does not start.
The generator continues to run.
The generator continues to run.
The generator stops.
The generator stops.
The inverter switches off, there-
fore no voltage is supplied but
the engine carries on running
until it goes off.
The inverter switches off, there-
fore no voltage is supplied but
the engine carries on running
until it goes off.
The inverter switches off so no
voltage is supplied to cool the
generator, but the engine car-
ries on running.
The generator stops.
TEC29 EV
Measures
Charge the battery.
Change the oil (see chapter
"Changing the oil (fig. 7,
page 6)" on page 26), then
restart the generator by pressing
and holding down the start but-
ton.
Refuel.
Fill up with oil (see chapter
"Checking the oil level" on
page 21).
Check the system by referring to
the troubleshooting table.
If the problem persists, contact
the manufacturer's branch office
in your country (addresses on the
back page).
Reduce the connected load and
start the generator again.
Check the connected consum-
ers then start the generator
again.
Leave the engine to cool down
for a few minutes then start the
generator again.
Reduce the connected load and
start the generator again.
EN