Servicing the generator
➤ Undo the fastening screws (1).
➤ Remove the mounting plate (2) with the generator from the housing (3).
10.3
Finishing maintenance work
➤ Connect the generator to the positive terminal of the supply battery.
➤ Switch the generator to standby with the main switch (fig. 5 1, page 5).
➤ Close the generator front door.
Changing the oil (fig. 7, page 6)
10.4
!
CAUTION!
Hot oil can cause burns.
A
NOTICE!
Only dispose of used oil at a specialist recycling station and observe the
local laws for environmental protection.
You may use the following oil:
• API SG or SF grade oil for four-stroke engines.
• SAE 10W-30 grade oil (can be used at any temperature).
• Oil with single grade oil viscosity.
Select the appropriate viscosity according to the average temperature on-site.
Change the oil as follows:
➤ Allow the generator to run until warm so that the oil can drain off faster and com-
pletely.
➤ Place a suitable receptacle under the drain plug (1).
➤ Take out the drain plug (1).
✔ The oil drains off.
➤ Pour fresh oil into the nozzle.
The amount of oil is: 0.6 l.