1. USER GUIDE
Wireless (RF 868MHz) connecting boxes specially designed to control your Under Floor Heating managed by
Normally Closed actuators.
Possibility to extend easily the number of zones up to 12, with the extension module.
Work in combination with our RF thermostat range (Digital and Basic)
2. TECHNICAL CHARACTERISTICS
Operating Temperature
Regulation characteristics
Supply Voltage
Outputs:
Pump or accessories
Actuators
Radio Frequency
CE Directives
Your product has been
designed in conformity
with the European
Directives.
Product conformed to :
Classification :
Contribution :
Protection
Combination
3. LED EXPLANATION
In normal working mode:
For the LED on each zone
Green Flash:
RF signal reception from the thermostat assigned on this zone.
Red:
Heating demand indicator (Water circulation on this zone)
Red Blinking:
RF alarm, the communication between thermostat and the Master has been lost.
Check the thermostat batteries. (When batteries thermostat must be changed, always replace the 2 batteries)
* If all zones are Red blinking, check the RF antenna connection before replacing all thermostat batteries.
Pump: Green when the pump is active
H/C: Green when cooling, red when heating
4. POSSIBLE COMBINATIONS WITH EXTENSION MODULE (6 & 4 ZONES)
BT-M6Z02-RF 230V
Proportional Integral regulation or Hysteresis regulation. Regulation is defined by
thermostat linked to channel (see thermostat leaflet)
230VAC +- 10% 50Hz
Relay => 5A / 250VAC (Free contact)
Relay => 5A / 230 VAC ( L, N)
For easy installation we recommend a
maximum of 4 actuators by zones.
868, 3 MHz, <10mW.
Range of approximately 180 meters in open space.
Range of approximately 50 meters in residential environment.
R&TTE 1999/5/EC
LVD 2006/95/EC
EMC 2004/108/EC
RoHS 2011/65/EU
10 Zones => 1 Master 6 + 1 Slave 4 zones
12 Zones => 1 Master 6 + 1 Slave 6 zones
0°C to 50°C
24Vac +- 10% 50Hz
Relay => 5A / 250Vac (free contact)
Triac => 3A / 24Vac
Total number of actuators is limited by
transformer (60VA) and fuse (2,5A) and
power of actuators.
R&TTE 1999/5/EC
EMC 2004/108/EC
RoHS 2011/65/EU
UE 811/2013 and 2010/30/UE
IV
(2%)
IP 30
3
BT-M6Z02-RF 24V