6. HOW TO INSTALL CORRECTLY YOUR RF SYSTEM
The active antenna shouldn't be placed inside the
metallic box.
Metallic Box
The active antenna shouldn't be mounted near to
metallic parts.
Metallic Box
* For maximum radio sensibility, the active antenna must be placed at a minimum of 0.50 cm of any metallic
surfaces (Electrical Box) or vertical metallic pipes.
if you use several BT-M6Z02 RF as slave module, the antenna of each slave must be placed at a
minimal distance of 80cm one of the other to avoid any dysfunctionnement.
Careful!
X
Careful!
X
The active antenna sensitivity will be reduced if it
mounted in horizontal position.
Metallic Box
The active antenna must be mounted vertically.
Metallic Box
6
Careful!
X
Good
50 cm