Technical data
Fault
Compressor runs
intermittently
Unusual noises
Fault
Loud humming
12
Technical data
All MDC series refrigerators have the following features:
Connection voltage 12 V
Cooling device compartment temperature: +10 °C to +2 °C
Freezer compartment temperature: 0 °C to –18 °C
Relative humidity: maximum 90 %
Constant inclination: maximum 30°
Test/certificates:
complies with ErP/EuP directive
Overall capacity:
Freezer compartment:
Average power consumption:
Dimensions (W x H x D) in mm:
Weight:
The coolant circuit contains R-134a.
38
Possible cause
Battery capacity exhausted
Possible cause
A component of the refrigerant circuit
cannot move freely (touching the wall)
Foreign body jammed between the
cooling unit and the wall
Fan noise
or 24 V
g
g
MDC065
MDC065K
485 x 673 x 475
MDC065(K), MDC090(K)
Remedy
Charge the battery
Remedy
Bend the component
carefully away from the
obstruction
Remove the foreign body
–
64 l
10 l
45 W
20 kg
MDC090
MDC090K
90 l
10 l
485 x 830 x 475
28 kg
EN