2. Installation location

Fig. 2-1

3. Installing the indoor unit

1
2
4
5
7
8
Fig. 3-1
A
2
B
75
233
246
Fig. 3-2
2.1. Outline dimensions (Indoor unit) (Fig. 2-1)
(mm)
Select a proper position allowing the following clearances for installation and main-
tenance.
Mount the indoor unit on a ceiling strong enough to withstand the weight of
the unit.
2.2. Outline dimensions (Outdoor unit)
Refer to the outdoor unit installation manual.
3.1. Check the indoor unit accessories (Fig. 3-1)
3
The indoor unit should be supplied with the following accessories
(contained in the inside of the intake grille).
6
3.2. Preparation for installation (Fig. 3-2)
(mm)
236
3.2.1. Suspension bolt installing spacing
3.2.2. Refrigerant and drain tubing location
2
85
86 2
138
In case of the rear pipe arrangement, make sure to remove the shaded portions
from the D independent piece. Then put the D independent piece back in initial
position.
(The heat exchanger might be clogged because of dust)
C
D
233
246
Models
W
RP35, 50
960
RP60, 71
1280
RP100, 125, 140
1600
Warning:
Accessory name
Washer
4 pcs
1
Pipe cover
1 pc Large size (For gas tubing)
2
Pipe cover
1 pc Small size (For liquid tubing)
3
Band
4 pcs
4
Joint socket
1 pc Marked with "UNIT"
5
Socket cover
1 pc
6
Drain tubing cover
1 pc
7
8
Flare nut
1 pc ø6.35 (RP60 only)
Models
A
RP35, 50
917
RP60, 71
1237
RP100, 125, 140
1557
Models
C
RP35, 50
184
RP60
179
RP71-140
180
A Front side outlet
B Left side outlet
C Right side outlet
D Independent piece (Removable)
E Right drain tubing
Q'ty
(mm)
B
960
1280
1600
(mm)
D
203
203
200
F Left drain tubing
G Gas tubing
H Liquid tubing
I Rubber plug
J with Joint socket 5
3