TROUBLESHOOTING

Symptom
LED does not
illuminate
LED orange
main
Little air flow
No air flow
Please call OK INTERNATIONAL if: your system is still not working properly,
or if the LED is green with no air flow.

SPECIFICATIONS

Static Pressure:
Flow Rates:
Noise Level:
Weight:
Size H x W x D:
Voltage:
Frequency:
Power:

WARRANTY

OK International warrants the BVX-100 system, except consumables (e. g.
arms, nozzles and filters), against any defects in materials or workmanship for
one year from the date of purchase by original owner.
If the product should become defective within the warranty period, OK
International Inc., will repair or replace it free of charge at its sole option. The
replacement item(s) will be shipped, freight prepaid, to the original purchaser.
The warranty period will start from the date of purchase. If the date of
Possible Cause
No power
Blocked filter or air flow Change filter (See Replacement of
Air leak
Blower does not work
Interlock switch open
5 in H20 (1250 Pa)
50 CFM (85 m3/hr) w/HEPA filter
< 55 dbA
14.3 lbs. (6.5 kg)
11.5" x 12" x 9" (29cm x 30cm x 23cm)
90 – 264 VAC
50 – 60 Hz
85 Watt
www.okinternational.com
Solution
Check electrical outlet for output
Check On/Off switch
Check power cords
Check for main filter
Check for safety interlock switch
Filters. Note: change pre-filter first. If
the LED is still orange, replace the
filter.)
Housing not installed correctly
Arm adaptor not installed correctly
No electrical power
No filter installed
Housing not closed correctly
8