Commissioning / operation

8
Commissioning / operation
Before commissioning, ensure that:
• the devices have been installed in accordance with the standards
• the equipment is not damaged
• no extraneous particles are present in the devices
• the terminal chamber is clean
• the connections have been correctly made
• the cables are inserted properly
• all bolts and nuts are tightened firmly
• the cable entries and stopping plugs are connected firmly
• unused wire lead-ins are sealed with stoppers certified as compliant with Directive
94/9/EC and unused drilled holes are sealed with stoppers certified as compliant
with Directive 94/9/EC
Type 8571/16
The coupler socket Type 8571/116is only supplied with power when a plug is inserted.
It should only be used in conjunction with Type 8571/12 or 8578/12 plugs from R.STA-
HL. Make sure that the socket's hinged cover is closed with the bayonet ring when the
plug is pulled out.
9

Servicing

9.1 Maintenance
Maintenance, repair and servicing work on the devices must only be performed by person-
nel who are both authorised and suitably trained for this purpose. Observe the relevant
national regulations in the country of use!
Before any maintenance work commences, the devices must be disconnected from the
power supply!
To prevent contact corrosion, pull out the plug from the socket at regular intervals.
The following must be checked during maintenance:
• that the cable is securely seated,
• the maximum permissible temperatures according to EN 50 014 are adhered to,
• the plastic enclosure shows no signs of crack formation,
• the socket sleeves are free of dirt,
• the gaskets and seals are checked for damage,
• the function is in accordance with regulations,
• the surface of the plug pins must not be damaged!
Subsequent to each short circuit in the switch's main circuit, the entire socket flange must
be replaced. This is because the switching contacts of a hermetically-sealed apparatus
can not be tested for functionality.
18