VISION 2
RFF4000 can be used with Powerpak,
TORNADO
or
respirator systems provided that the
correct filter type is fitted.
In such cases, ensure that this manual is
read in conjunction with the following
publications:
Product
Publication
User Manual
Powerpak
Filter Manual
User Manual
Tornado
Filter Manual
User Manual
Proflow
Filter Manual
Please contact our Customer Services
Department if you require any further
information.
VISION 2 is easily dismantled for repair
and servicing, requiring only a pozi-drive
screwdriver to undo the front fitting.
Servicing should only be carried out by
trained, authorised personnel.
FILTERS
The following filters are available for use
with VISION 2:
Code
Filter Type
EC200R
A2
EC201R
B2
EC203R
K2
EC213R
ABEK2
EC219R
AX
EC220R
A2 P3
EC221R
B2 P3
EC222R
E2 P3
EC223R
K2 P3
EC230R
A2 B2 E1 P3
EC233R
ABEK2 P3
EC238R
AE1Hg P3
EC239R
AXP3
EC251R
P3
Proflow
powered
Article No.
1065558
1064883
1070613
1070782
009741
009752
Standard
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 14387 : 2004
EN 143 : 2000
WEARING
1.
Check that the facemask, inhale
and exhale valves; and head harness are
clean and undamaged.
2.
Check that the filter(s) fitted is/are
not clogged, saturated or time expired
and is/are suitable for the hazards that
may be encountered. Fit new filter(s) if
necessary. Check that filter seal(s) is/are
in place and is/are in good condition.
Replace if necessary.
3.
Check that the exhale valve is
clean and in good condition. Ensure that
the valve flap is not distorted.
4.
Hang the mask around your neck
by the neckstrap, fully slacken the head
harness and remove the filter cover(s).
The neckstrap pin can be pressed into
the hole at the top of the head harness to
support the facemask in an upright
attitude, keeping it free from dust and
debris when the mask is not in use.
5.
Hold the head harness with the
thumbs inside the harness. Fit the chin
into the chin-cup and pull the harness
over the head. Gently tighten the harness
straps; lower first, then the middle straps
(if fitted) and finally the top strap. A good
seal should be achieved without over-
tightening, which will cause the facemask
seal to distort and cause discomfort.
6.
Check the mask seal to the face by
covering the filter inlet(s) with a hand or
the filter blanking cover and inhaling. The
mask should pull onto the face. Hold your
breath for 10 seconds and check that the
mask seal is maintained over the 10
second period. If the seal fails, indicated
by the mask pulling away from the face,
check that the filter(s) is/are properly
fitted and adjust the mask seal to the
face, then repeat the test. If it fails a
second
time,
serviced.
WARNING:
If the mask does not seal correctly
after servicing, DO NOT use.
2
the
mask
should
be