Dometic GROUP RMD10 Série Instructions De Montage page 24

Réfrigérateur à absorption
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Connecting the refrigerator
5.2
Connecting to DC and AC
A
NOTICE!
The electrical installation and repairs must only be performed by a spe-
cialist in accordance with the applicable regulations and standards.
I
NOTE
• The device plug must not be placed directly behind the ventilation
grill in order to prevent the air circulation from being impaired and to
protect the device plug from splashes of water.
• The device plug of the AC connection cable must not be cut off.
• The connection cables must be laid so that they do not come in con-
tact with hot parts of the unit/burner or with sharp edges.
• Changes to the internal electrical installation or the connection of
other electrical components (e.g. extra third party fans) to the inter-
nal wiring of the refrigerator will void any claims from the guarantee
and product liability.
• The refrigerator has a CI bus interface and can be controlled through
a compatible central vehicle display.
Circuit diagram of the refrigerator (fig. i, page 11)
Item in
fig. i,
Description
page 11
1
Fan 2 (if options module is not available)
2
Fan 1 (if options module is not available)
3
S+ (optional)
4
Heating element DC
5
DC relay with 20 A fuse for heating cartridge
6
NTC 1: Refrigeration room
NTC 2: Outside temperature (optional)
7
Gas valve
8
AC power supply
9
Heating element AC
10
Gas burner
11
Connection block