Operation (Turn Off) - FireWare Cirrus Mode D'emploi Utilisateurs

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

User Manual
EN
FireWare Cirrus
To recharge the battery, use the charger that is provided. An empty battery can be fully recharged in
10-12 hours. Connect the charger to the mains (100-240 V/50-60 Hz) and then connect the charger
cable to the battery (3). The red led indicator will be on during recharge. When the battery is fully
charged, the green led indicator will be on. After recharge, the charger must be disconnected from the
mains.
Use
TAKE NOTE: Make sure the fluid is clean at all times, so no dirt or dust can be sucked into the pump.
1.
Pour the FireWare Cirrus Fluid in the fluid tank using a funnel and close the tank filler cap
firmly. Clean any possible fluid spillage using a dry cloth.
TAKE NOTE: Use only FireWare Cirrus Fluid. Other smoke fluid, like standard water-glycol smoke
fluid, will block the evaporator and severely damage the machinery.
2.
Connect the connection of the smoke fluid hose (5) to the connection on the fluid tank.
You will hear a click.
3.
Connect the battery to the machine. To do so, connect the battery connector (6) to the
connection (12) at the back of the smoke generator.
4.
Push the grey starter button in briefly. The machine will now heat up for 1 second
without smoke fluid being pumped. Push in once again to generate smoke. Keep the button
pushed in to generate smoke continuously. When you let go of the button the pump will
stop, but will continue generating smoke for 15 seconds to clear all smoke fluid in the
evaporator.
5.
After approximately 40 seconds, the FireWare Cirrus will go into sleep mode. The device
then only uses 1.5 milliampère. The Cirrus can therefore remain connected to the power
supply without any notable power use. Standby time is approximately 250 hours. You can
also use the FireWare Cirrus when connected to the mains.
Built-in
If you want to build the FireWare Cirrus in, make sure a smoke-free air supply is always guaranteed.
An excessively high smoke concentration in the air can condense inside the machine and this can lead
to moisture damage.
When building it in, always ensure that:
No smoke circulates back into the smoke generator.
No condensation moisture runs back into the machinery.
No objects protrude in front of the smoke generator nozzle.
5.

Operation (turn off)

Before you store the FireWare Cirrus, recharge the battery first completely. This will extend its life
expectancy considerably.