TECHNICAL DATA

Receiving Lens
Measuring Range
Minimum distance
Maximum distance
Distance Measurement
Typical tolerance
(applies for 100 % target reflectivity (white painted wall), low
background illumination, 25 ºC)
Maximum tolerance
(applies to targets with lower reflectivity, high background
illumination, or temperatures approaching the lower/upper
limit)
Smallest unit displayed
Laser Spot Size
10 m distance:
30 m distance:
Laser Class
Laser Type
Laser Radiation
Vertical Angle
Horizontal Angle
Display Type
Laser auto off time
Device auto off time
Power Type
Battery Life
Operating Temperature Range
Storage Temperature Range
Weight without Battery
Dust and Water resistance

SPECIFIED CONDITIONS OF USE

The laser distance measurer can be used for measuring distances
Do not use this product in any other way as stated for normal use.
ENGLISH
15 mm x 9.5 mm
0.15 m
30 m
± 2.0 mm
(an addidional tolerance of 0.1 mm/m should be taken into account)
± 4.0 mm
(an addidional tolerance of 0.15 mm/m should be taken into account)
1.0 mm
20 x 35 mm
40 x 65 mm
2
650 nm, < 1 mW
± 1 degree
+ 1 degree
LCD (25 mm x 25 mm)
90 sec
180 sec
AAA 2x (Alkaline Battery)
10000 (Single Measure)
0°C to +40°C
-10°C to +60°C
72 g
IP54

ERROR CODE TABLE

Code
Description
Err500
Hardware problems
Solution
Turn the meter off and back on. If the
problem remains, return the meter to
the nearest service center.
2

Publicité

Table des Matières
loading

Table des Matières