ote – Early alarm
N
The early alarm can only be activated if at least one of the
two alarm functions (
• If the alarm is triggered, the alarm symbol (12) will begin to ash
and an alarm will sound.
• Press the ALARM ON/OFF button (18) to stop the alarm.
Otherwise, it will stop automatically after 2 minutes. Otherwise,
after two minutes snooze mode is activated automatically.
ote – Snooze function
N
• While the alarm signal is sounding, press the SNOOZE button
(20) to activate the snooze function. The alarm symbol (12)
begins to ash in the display. The alarm signal is stopped for
8 minutes, after which it will sound again.
• The snooze function can be activated three consecutive times.
6.4. Weather
• The weather station indicates a trend as to how the values for
the outdoor temperature (8), room temperature (9) are likely to
develop over the next few hours.
Display
6.5. Maximum and minimum temperature values
• The base station automatically stores the maximum and
minimum outdoor/indoor temperature.
• Repeatedly press the MEM button (19) to switch between the
current temperature, minimum temperature (MIN) and maximum
temperature (MAX). The maximum and minimum temperatures
are displayed for 10 seconds.
• Press and hold the MEM button (19) for approx. 3 seconds to
reset the stored maximum and minimum values.
6.6 Low battery capacity
Measuring station
If the batteries need to be replaced, the symbol for low
battery charge
will appear next to the outdoor
temperature display on the base device. Replace the batteries
immediately.
Base station
If the batteries need to be replaced, the symbol for low
battery charge
will appear next to the time display on
the base device. Replace the batteries immediately.
6
/
) has already been activated.
Trend
Increasing
Constant
Decreasing
ote – Replacing the batteries
N
• Note that the stations have to be resynchronised each time
after you change the batteries in the measuring or base
station.
• To do this, remove the batteries from the other station and
then reinsert them, or change them as required.
7. Care and Maintenance
Only clean this product with a slightly damp, lint-free cloth
and do not use aggressive cleaning agents. Make sure that
water does not get into the product.
8. Warranty Disclaimer
Hama GmbH & Co KG assumes no liability and provides no
warranty for damage resulting from improper installation/
mounting, improper use of the product or from failure to
observe the operating instructions and/or safety notes.
9. Technical Data
Base station
Power supply
2 x AA batteries
Measuring range
-5°C – +50°C/
Temperature
23°F – 122°F
Measurement
increments
0,1°C / 0,2°F
Temperature
Temperature
measurement cycle
Radio-controlled
DCF clock
Max. number of
measuring stations
Range
Measuring station
3,0 V
3,0 V
2 x AAA batteries
-10°C – +60°C/
14°F – 140°F
0,1°C / 0,2°F
~ 45 s
~ 45 s
Yes
No
3
30 m