4.
Technical Data
Safety Switch
Electrical Data
Temperature Range
Storage Temperature
Supply Voltage
Rated operating current I
Rated insulation voltage U
Current Consumption
Short Circuit Protection
Reverse Polarity and Overload Protection
Protection Class
Overvoltage category
Degree of pollution
Response Time:
− Actuator
− Inputs
Duration of risk
Time delay before availability
Switching Frequency
Safety Output
Safety Output
Number of Safety Outputs
PNP Safety Output/Switching Current
Safety Output Voltage Drop
Utilisation category
Safety Input
Number of Safety Inputs
Current consumption safety input
Supply Voltage
Signal Output
Number of Signal Outputs
PNP Signal Output/Switching Current
Signal Output Voltage Drop
Utilisation category
Test pulse duration
Test pulse interval
ZVEI classification
Source
Sink
Mechanical Data
Typical switching distance S
Safety Switch RFID
e
i
typ
−25...70 °C
−25...85 °C
20,4...26,4 V DC (PELV unit)
0.6 A
32 V
0.5 mA
yes
yes
III
III
3
≤ 100 ms
≤ 0,5 ms
≤ 200 ms
≤ 5 s
1 Hz
Semiconductor
2
< 250 mA
< 1 V
DC12: 24 V DC / 0,25 A
DC13: 24 V DC / 0,25 A
2
5 mA
20,4...26,4 V DC (PELV unit)
Semiconductor
1
50 mA
< 2 V
DC12: 24 V DC / 0,05 A
DC13: 24 V DC / 0,05 A
≤ 0,3 ms
1000 ms
ZVEI CB24I
C2
C1, C2
12.0 mm
25