Volume (CC 7)
Message which controls the sections volume.
Data format: BnH 07H vvH
n=channel number
:0H–EH (1–15)
vv=volume value
:00H–7FH (0–127)
Expression (CC 11)
Message which controls the sections expression.
Data format: BnH 0BH vvH
n=channel number
:0H–EH (1–15)
vv=expression value
Bank Select LSB (CC 32)
Controller
transmitted
Program Change and Bank Select MSB in order
to select a specific bank of sound. It can be
transmitted using the COMBIN. PRG function
and when stored in the combinations and Tutti.
Data format: BnH 20H vvH
n=channel number
:0H–EH (1–15)
vv=bank LSB number :00H–7FH (0–127)
Sustain (CC 64)
Message which controls the Sustain / Damper
effect.
Data format: BnH 40H vvH
n=channel number
:0H–EH (1–15)
vv=switch
:00H (0) off
(received as 00H-39H)
:7FH (127) on
(received as 40H-7FH)
All Sounds Off (CC 120)
Terminates all voices currently on for the specific
channel.
Data format: BnH 78H 00H
n=channel number
:0H-EH (1–15)
Reset All Controllers (CC 121)
Controllers are set to the default value.
Data format: BnH 79H 00H
n=channel number
:0H–EH (1–15)
- This message is transmitted only.
All Notes Off (CC 123)
Terminates all notes currently on for the specific
channel.
Data format: BnH 7BH 00H
n=channel number
:0H–EH (1–15)
:00H–7FH (0–127)
in
combination
Program Change
Messages for selecting sounds, timbres or
programs in external modules. It also can be
received by the organ to recall combinations,
Tutti and Crescendo steps.
Data format: CnH mmH
Transmitted:
n=channel number
mm=Program Ch. number:00H–7FH (0–127)
Received:
n=channel number
mm=Program Ch. number:
00H (0): general HR
01H-06H (1-6): general combinations 1-6
10H (16): Pèdale HR
of
11H-16H (17-22): Pèdale combinations 1-6
20H (32): Grand Orgue HR
21H-26H (33-38): Grand Orgue combin. 1-6
30H (48): Recit HR
31H-36H (49-54): Recit combin. 1-6
40H (64): Positif HR
41H-46H (65-70): Positif combin. 1-6
60H (96): Tutti OFF
61H (97): Tutti ON
6FH (111): Crescendo -- (OFF)
70H–7FH (112-127): Crescendo steps 1-16
STANDARD
MESSAGES
Device Inquiry
Instrument information sent after switching on
and when a Device Inquiry Request is received.
Data format: F0H 7EH 00H 06H 02H 31H 00H
1CH 20H 00H xxH yyH zzH vvH F7H
F0H: Exclusive status
7EH: Universal Non Realtime message
00H: channel
06H: general information
02H: device ID reply
31H: Viscount ID
00H 1CH: device family code
20H 00H: device family member code
xxH yyH zzH vvH: software version
F7H: End of Exclusive
Master Fine Tuning
Parameter: Tuning
Video page: Main page
Data format: F0H 7FH 7FH 04H 03H vvH nnH
F7H
F0H: Exclusive status
7FH: Universal Realtime message
7FH: channel (any)
04H: Sub-ID #1=Device Control message
03H: Sub-ID #2=Master Fine tuning
vvH nnH: fine tuning value
00H 00H: A4=415,3 Hz
00H 40H: A4=440 Hz
7FH 7FH: A4=466,2 Hz
F7H: End of Exclusive
56
Viscount
Chorum
:0H–EH (1–15)
:FH (16)
SYSTEM