Safety

Important Safety Instructions

SAVE THESE INSTRUCTIONS - This manual contains
important instructions that should be followed during
installation, operation, and maintenance of the product.
Save this manual for future reference.
This is the safety alert symbol. When you see this
symbol on your pump or in this manual, look for one of
the following signal words and be alert to the potential
for personal injury!
indicates a hazard which, if not avoided, will
result in death or serious injury.
indicates a hazard which, if not avoided,
could result in death or serious injury.
indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE addresses practices not related to
personal injury.
Carefully read and follow all safety instructions in this
manual and on product.
Keep safety labels in good condition. Replace missing or
damaged safety labels.
Install this tank in vertical position only. If your
installation requires a horizontal tank, contact your
dealer for available steel tanks.
California Proposition 65 Warning
This product and related accessories contain
chemicals known to the State of California to cause
cancer, birth defects or other reproductive harm.
Rules For Safe Installation And Operation
Risk of explosion. Installation must comply
with all applicable state, provincial, and local statutes,
codes and ordinances. Non-compliant installation
may result in product failure, property damage, and/or
personal injury.
1. Read the owner's manual and Rules for Safe
Installation and Operation and Installation
instructions carefully. Failure to follow these rules
and instructions could cause serious bodily injury
and/or property damage.
2. Always test water from well for purity before
using. Check your local health department for
testing procedure.
3. Before installing or servicing your tank, BE SURE
pump electric power source is disconnected.
4. Release all pressure before working on tank or
system. Make sure all air pressure has been released
before removing tank flanges.
5. BE SURE your pump electrical circuit is
properly grounded.
6. Remove bleeder orifices, air volume controls or other
air charging devices in existing system.
Risk of explosion. To prevent possible serious
or fatal in jury and/or damage to equipment, system
pressure must be less than 125 pounds per square
inch gauge (psig) under any circumstances. Failure to
follow this instruction can result in tank explosion.
If system discharge pressure can exceed 125 psig,
install a relief valve capable of passing the full pump
volume at 125 psig. Install relief valve in pump
supply line to tank, as close to tank as possible.
Risk of freezing. To avoid possible
equipment failure, severe injury, and property damage,
do not allow pump, tank, or piping system to freeze.

General Safety

All tanks are factory pre-charged with air. When
installing tank, adjust pre-charge to 2 psig below pump
cut-in pressure setting. To do this, bleed air from or add
air to the valve on top of the tank.
NOTICE Always set pre-charge with NO WATER in tank.
Check pressure frequently with an accurate tire pressure
gauge until correct pressure has been reached. For
correct pre-charge pressure settings, see Table 1.
Pressure Switch Setting
20-40 psig
30-50 psig
40-60 psig
50-70 psig
Table I
2
Tank Precharge (psig)
18
28
38
48