Do not use the infrared cabin
- in case of fever or acute infection
- if suffering from thrombosis, infections or open wounds
- if suffering from a metabolic crisis
- under the influence of alcohol or drugs
Children, the elderly and persons not sensitive to heat, as well as handicapped persons, must not be
permitted to stay in the infrared cabin by themselves.
Before it is heated up, ensure that there are no pets in the cabin.
The infrared cabin is to be used exclusively for the thermal application. Improper usage (e.g. for drying of
laundry or the like) is prohibited under all circumstances.
Since odours may be generated during initial start-up, the cabin must be heated for at least one hour and
then well ventilated before being used for the first time.
According to VDE 0100, installation and maintenance of the thermal cabin with electronic controls
may only be carried out by a professional electrician.
There is a risk of serious injury or death from exposure to 230 V mains voltage.
WARNING!
Extensive heating systems with 230 V mains voltage are located in the floor and wall elements.
After the infrared cabin has been set up in accordance with the assembly instructions, it is strictly prohibited
to install screws, nails, staples and the like in the cabin elements, as well to partially or completely cover the
heating surfaces (with towels or pillows, for example).
FIRE HAZARD, RISK OF FATAL INJURY!
Instructions for care
We recommend that you sit on sauna towels in the cabin so that the sweat does not run onto the wood parts.
Air out the cabin well after each session.
Also always ensure that the room in which the cabin is located is well ventilated.
The heating surfaces inside the cabin are maintenance free. They should not be covered or allowed to come
into contact with moisture. Stubborn stains on the wood can be removed with emery paper.
It is unavoidable that small amounts of resin will appear on the surface of the wood. The dry resin residues
can be removed with fine sandpaper.
Always use wood glue, never chemical adhesives, inside the cabin.
The bench and slatted floor should be thoroughly cleaned at least once per year outside of the cabin using a
soft brush and clear water.
Technical information
Prerequisite for connecting the infrared cabin: a socket with a separate 16 A fuse
For information on the operation and connection of the IR controller, see the assembly instructions of the
control panel and the IR controller.
The film sensor has already been fitted by us and is located in one of the rear wall elements.
The maximum wattage of the bulb used for cabin lighting should not be more than 40 W.
Ensure that the socket is accessible at all times.
If it needs to be replaced at a later date, the included mains cable must be ordered from weka customer
service.
In order to ensure all-pole disconnection of the unit from the mains, the plug must be removed from the
socket.
Two sockets for heating circuits 1-3 are located on the power element.
When connecting the radiant heater cables, it doesn't matter which of the two sockets
is used.
In order to prevent the glass door from sagging, screw down the Allen screw of the fittings tightly.
Door leaf
The adjustable eccentric, item 42, permits easy adjustment of the glass door leaf even at a later point in time.
The internal parts of the door fittings are removed, and the eccentric is rotated in the appropriate direction.
During installation of the door grips, ensure that the metal grip piece is on the outside of the door.
7
Copyright HRB3662
Technische. Änderungen vorbehalten!