Control electronics
Rated control supply voltage
Rated control supply current
Rated frequency
Power electronics
Rated operating voltage
Rated frequency
Permissible ambient temperature
Accessories
Box terminal block
Terminal covers for box terminals
Terminal covers for cable lug and
busbar connection
Spare parts
Fan
115 V AC front side
output side
230 V AC front side
output side
*) only up to 600 V in inside delta connection
Recommendation on procedure for 3RW44 commissioning
Suggested setting
Starting mode: Voltage ramp and current limiting
Start
voltage %
Application
Conveyor belt
70
Roller conveyor
60
Compressor
50
Small fan
30
Pumps
30
Hydraulic pump
30
Stirrers
30
Centrifugal machines
30
Milling machines
30
Large fan
30
Mill
50
Crusher
50
Disk saw/ribbon saw
30
NOTICE
This table provides example set values. They serve as reference for this information only and are non-binding.
The set values depend on the particular application and must be optimized during commissioning.
20
3RW44..-.BC3.
V
AC 115 (-15 % / +10 %)
AC 230 (-15 % / +10 %)
mA —
Hz
50 ... 60 (±10 %)
50 ... 60 (±10 %)
3RW44..-.BC.4
V
AC 200 ... 460 (-15 % / +10 %)
AC 400 ... 600 (-15 % / +10 %)
Hz
50 ... 60 (±10 %)
50 ... 60 (±10 %)
°C
0 ... +60
0 ... +60
SIRIUS 3RW44
3RW44 2.
3RT19 55-4G up to 70 mm
Included in scope of supply
3RT19 56-4G up to 120 mm
3RT19 56-4EA2
3RT19 56-4EA2
3RT19 56-4EA1
3RT19 56-4EA1
3RW49 36-8VX30
3RW49 36-8VX30
3RW49 36-8VX40
3RW49 36-8VX40
Startup parameters
(Voltage ramp + current limiting)
Starting time
Current limit value
s
10
deactivated
10
deactivated
10
4 x I
e
10
4 x I
e
10
4 x I
e
10
4 x I
e
30
4 x I
e
30
4 x I
e
30
4 x I
e
60
4 x I
e
60
4 x I
e
60
4 x I
e
60
4 x I
e
3RW44..-.BC4.
3RW44..-.BC.5
3RW44..-.BC.6
AC 400 ... 690 * (-15 % / +10 %)
50 ... 60 (±10 %)
0 ... +60
3RW44 3.
3RW44 4.
2
3RT19 66-4G up to 240 mm
2
3RT19 66-4EA2
3RT19 66-4EA1
3RW49 47-8VX30
3RW49 47-8VX40
Stopping mode
Breakaway pulse
deactivated (0 ms)
Torque control
deactivated (0 ms)
Torque control
deactivated (0 ms)
Coasting down
deactivated (0 ms)
Coasting down
deactivated (0 ms)
Pump stop
deactivated (0 ms)
Coasting down
deactivated (0 ms)
Coasting down
deactivated (0 ms)
Coasting down
deactivated (0 ms)
Coasting down
deactivated (0 ms)
Coasting down
80 % / 300 ms
Coasting down
80 % / 300 ms
Coasting down
deactivated (0 ms)
Coasting down
3RW44 5.
3RW44 6.
2
3RW49 66-8VX30
3RW49 57-8VX30
3RW49 57-8VX30
3RW49 66-8VX40
3RW49 57-8VX40
3RW49 57-8VX40
Stopping parameters
Parameters
Stopping time
Stopping torque
s
%
10
10
10
10
X
X
X
X
10
10
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
3ZX1012-0RW44-0AA0