Hilti DD 160 Mode D'emploi Original page 20

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
Risk of injury due to electric shock! Do not continue operating the diamond core drilling machine if the
indicator on the ground fault circuit interrupter does not go out when the 0 or the TEST button is pressed.
▶ Have your diamond core drilling machine repaired by Hilti Service.
4. Press "I" or "RESET" on the portable residual current device (PRCD).
➥ The drilling performance indicator shows orange.
6.3
Operating diamond core drilling machine without a wet-type industrial vacuum extractor
1. Slowly open the water flow regulator until the water flows at the desired rate.
The diamond core drilling machine can be operated with or without water collection system. With
the water collection system, the cooling water is drained away through a hose, without the water
collection system the water runs off in an uncontrolled manner. For operation with water collection
system, first install the water collection system → page 12.
In both applications, upward drilling is not allowed.
2. Push the ON/OFF switch to the "I" position.
3. Release the carriage lock.
4. Turn the hand wheel until the diamond core bit is in contact with the work surface.
5. When you start drilling apply only light pressure until the core bit has centered itself and only then,
increase the pressure against the working surface.
6. Observe the drilling performance indicator.
Initially, the drilling performance indicator shows orange. Optimum drilling performance is achieved
when the drilling performance indicator shows green. Reduce the pressure against the work
surface if the drilling performance indicator shows red.
6.4
Operating diamond core drilling machine with a wet-type industrial vacuum extractor
WARNING
Danger of electric shock! There is a possibility of water flowing over the motor and cover if the vacuum
removal system is faulty.
▶ Cease operations immediately if the vacuum removal system is not working.
1. Install the water collection system → page 12 and connect the wet-type industrial vacuum extractor.
2. Switch on the wet-type industrial vacuum extractor; do not use automatic mode.
3. Slowly open the water flow regulator until the water flows at the desired rate.
4. Push the ON/OFF switch to the "I" position.
5. Release the carriage lock.
6. Turn the hand wheel until the diamond core bit is in contact with the work surface.
7. When you start drilling apply only light pressure until the core bit has centered itself and only then,
increase the pressure against the working surface.
8. Observe the drilling performance indicator.
Initially, the drilling performance indicator shows orange. Optimum drilling performance is achieved
when the drilling performance indicator shows green. Reduce the pressure against the work
surface if the drilling performance indicator shows red.
6.5
Using the Rota-Rail (column swivel)
The Rota-Rail allows quick and easy access to the hole or core being drilled, with no need to partly or fully
dismantle the system.
WARNING
Risk of injury caused by incorrect use! The drill stand can be damaged or it can break.
▶ Never use the Rota-Rail as a column extension.
1. Lock the carriage with the carriage lock. Check to ensure that it is securely fastened.
2. Remove the end stop screw from the rear section of the column.
3. Secure the Rota-Rail so that the toothed racks are facing the same direction.
14
English
Printed: 09.08.2019 | Doc-Nr: PUB / 5069575 / 000 / 07
434952
*434952*
11

Publicité

Table des Matières
loading

Table des Matières