Instruction manual TECNO line
ByTecnoplus
s.r.l.
CENTRAL VACUUM SYSTEMS
PROBLEM
There is no suction from any of the
suction sockets
There is no air suction from just one
suction socket
Filter alarm with clean fi lter cartridge
The air suction is weak
18
CAUSE
Only for TECNO
Alarm signalled on the display
The power cable is unplugged Connect the power cable
The start button is on OFF
position
The micro line cable is not
connected
The thermal protection of the
motor has intervened
The overcurrent circuit
breaker has tripped
The electric contacts are interrupted or the
micro-switch of the suction socket is out
of order
PRIME
Only for TECNO
Depression of the system
equal to or lower than 95
mbar
More than one suction socket is being used at
the same time and/or the service suction socket
is working
The fl exible hose or the
cleaning accessories are
broken
The fi lter cartridge is dirty
The sealing gasket of the dust
bin is damaged
There is a clogging in the suction
pipes of the pipe network
The air exhaust outlet is
blocked
Only for TECNO
The dust bag is full
SOLUTION
PRIME
units
Eseguire RESET dell'allarme
Press the Start button
Connect the activation cable
(sensor)
Allow a few minutes stop for
the motor to cool down
Proceed with the manual reset
of the circuit breaker
Call the Technical Service
units
Check possible losses in the
system
Reduce the opening time of
the vacpan inlet
Call the Technical Service
Use only one suction inlet at
a time
Check the fl exible hose and the accessories
are not damaged (change them if
necessary)
Clean the fi lter cartridge
Check sealing gasket
integrity
Call the Technical Service
Call the Technical Service
PRIME
units
Replace the dust bag
04/06/2019 Rev:1.0.0