6 - INSTALLATION
6.1 Preliminary operations
The suction system is shipped to the customer completely assembled and packed.
Before switching the machine on, the following checks are advisable:
• Check that the packaging is intact.
• Check that the appliance has not been damaged in any way and in particular check that all the
protruding parts are intact.
• Verify the correct tightening of the fi lter cartridge.
• Using the equipment list and the kit and accessories list, check that the equipment and the kit have
been exactly and completely delivered.
• Check that the Guarantee Certifi cate has been provided.
If any damage or irregularity is found or if any accessory is missing, do not install the appliance and
contact your Retailer.
6.2 Place of installation
The use of the vacuum cleaner requires a suction piping network installed by qualifi ed personnel who
has already selected the most suitable location.
Below you will fi nd the main indications to be followed for a correct installation:
• If the appliance will be connected to a pipe network on more than one fl oor, we suggest you to install
it in the lowest part of the building.
• install the system in service rooms (e.g. garage or store room) away from bad weather, dampness
and excessive temperature variations.
• Choose a place far from heat sources such as stoves and radiators.
• Make sure that there is suffi cient space around the system and that the surrounding area is well lit to
facilitate the interventions for maintenance and repairs.
When the vacuum cleaner, for specifi c installation needs, is installed on the highest fl oors of the
building with regard to the level where the pipe network is housed (attic, garret etc.), we suggest
you to install a vacuum cleaner featuring a power category higher than the one needed to clean the
desired surface.
For any further information, do not hesitate to contact the Manufacturer's Technical Service.
04/06/2019 Rev:1.0.0
- WARNING -
THESE PROCEDURES MUST BE CARRIED OUT
BY QUALIFIED PERSONNEL
2
9