Note: Technical parameters are measured at an ambient temperature of 32 °C and water temperature of 22
°C.
Attention:
Cooling unit may not be used under pressure!
Maximum height below water level: 200 cm (0.2 bar).
4.
Controller
5.
Setting temperature
In working state,press "△" or "▽" to adjust temperature. Chiller will start working after 5 minutes delay.
Temperature control range
For example: highest temperature is 35 °C,lowest temperature is 5 °C,that means temperature control range
is 5 °C to 35 °C.
6.
Menu's Description
In working state, press "Function" button to enter into menu system as follows:
No.
Menu
1
Setting (Set)
2
Temperature search
3
Working state
4
Equipment utilization rate
5
Version
7.
User Parameter
Menu
Setting Temperature
Language
Temperature Difference
Temperature Correction
Defrost Time
Liquid level device
Correspondence Address
Temperature
Backlight Time
9
Function
Shows and sets the user parameter.
Shows water temperature and defrost sensor temperature, fan
sensor temperature.
To check the status of relay output.
Displays the compressor running time.
Checks the current version of the software.
Default Values
18 °C
English
1 °C
0 °C
45 minutes
0: Forbidden
1
Celsius
0
Remark
Setting range: 5 °C ∽ 35 °C
English
\
\
\
0: Forbidden 1HP-3HP: Forbidden
1: Available
5HP-8HP: Available
Range: 1~32
Celsius/Fahrenheit
0: No backlight(0~255)

Publicité